HP rp5800 POS Terminal XZ956UT#ABA manual Weights & Dimensions, Temperature Range

Models: rp5800 POS Terminal XZ956UT#ABA

1 50
Download 50 pages 1.5 Kb
Page 17
Image 17

QuickSpecs

HP rp5800 Retail System

Technical Specifications

Weights & Dimensions

(configured with 1 HDD & 1 ODD)

Chassis

3.95 x 13.3 x 14.9 in

(H x W x D)

100 x 338 x 379 mm

System Volume

782.77 cu in

 

13.0 L

Tower Stand

1.1 x 7.0 x 7.9 in

(H x W x D)

29 x 178 x 200 mm

Packaging

9.0 x 19.7 x 23.4 in

(H x W x D)

229 x 500 x 594 mm

System Weight*

15.08 lb

 

6.84 kg

Shipping Weight*

16.28 lb

 

7.34 kg

Max Supported Weight

77.0 lb

(desktop orientation)

35.0 kg

 

 

Unit Environment and Operating Conditions

General Unit Operating Guidelines

Keep the POS System away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is operated within the specified operating range.

Leave a 10.2-cm (4-in) clearance on front side and power supply side of the POS System to permit the required airflow.

If within an enclosure, the front side should be 100% open. The clearance between the system and the cabinet must be at least 10 mm (0.4 inch) on the sides and top and at least 50-mm (2-inch) clearance in the rear with power supply venting area 100% open per the above bullet.

Never restrict airflow into the POS System by blocking any vents or air intakes.

Do not stack POS Systems on top of each other or place POS Systems so near each other that they are subject to each other's re- circulated or preheated air.

Occasionally clean the air vents on the front, back, and any other vented side of the POS System. Lint, dust and other foreign matter can block the vents and limit the airflow.

Temperature Range

Operating: 32° to 104° F (0° to 40° C)*

 

Non-operating: -22° to 149° F (-30° to 65° C)

Relative Humidity

Operating: 10% to 90% (non-condensing at ambient)

 

Non-operating: 0% to 95% (non-condensing at ambient)

Maximum Altitude

Operating: 10,000 ft (3048 m)

(unpressurized)

Non-operating: 30,000 ft (9144 m)

*Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.

NOTE: An optional thermal configuration is available to support 50C ambient temperatures. This is a factory configurable configuration only.

DA - 13982 North America — Version 12 — November 8, 2013

Page 17

Page 17
Image 17
HP rp5800 POS Terminal XZ956UT#ABA Weights & Dimensions, Unit Environment and Operating Conditions, Temperature Range