Type of Appliance Rinnai model number Operation Exhaust system Minimum/Maximum Gas Rate (Input) Electrical
Electrical Consumption
Ignition System
Hot Water Capacity
Temperature
Temperature (without remote)
Approved Gas Types
Installation
Energy Factor
Thermal Efficiency
Service Connections
Water Flow Control
Minimum/Maximum Water Supply Pressure
R70e (2526W)
Temperature controlled, continuous flow, gas hot water system
With or without remote controls, mounted in kitchen, bathroom, etc. Outdoor forced combustion
15,000 - 199,000 BTU/h (Natural Gas or Propane)
Appliance: | AC 120 Volts - 60 Hz |
Remote Control: | DC 12 Volts |
Normal | 63 watts |
Standby | 5.5 watts |
84 watts | |
Direct electronic ignition |
|
0.6 to 6.5 GPM (50° F rise) | 0.6 to 7.0 GPM (35° F rise) |
98° - 140° F |
|
120° F (factory default) |
|
Natural or Propane (ensure unit matches gas type)
Outdoors only |
|
Natural Gas: 0.81 | Propane: 0.80 |
Natural Gas: 84% | Propane: 84% |
Gas supply: 3/4 inch MNPT
Cold water inlet: 3/4 inch MNPT
Hot water outlet: 3/4 inch MNPT
Water flow sensor, electronic water control and
20 - 150 PSI (50 PSI or above is recommended for maximum flow)
FLOW TABLE
Water Flow Capacity Curves
(For 1 to 5 units manifolded in parallel)
| 40.0 |
|
|
|
|
|
|
| 35.0 |
|
|
|
|
|
|
(gpm) | 30.0 |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Rate | 25.0 |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Flow | 20.0 |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Hot Water | 15.0 |
|
|
|
|
|
|
10.0 |
|
|
|
|
|
| |
| 5.0 |
|
|
|
|
|
|
| 0.0 |
|
|
|
|
|
|
| 0 | 25 | 50 | 75 | 100 | 125 | 150 |
|
|
| ∆T – Temperature Rise (°F) |
|
|
|
| 1 Unit |
| 2 Units |
| 3 Units |
| 4 Units |
| 5 Units |
|
|
|
|
|
|
2526W SP-1