![Water Temperature Control Remote Controls](/images/new-backgrounds/38321/383213x1.webp)
Water Temperature Control Remote Controls
R70e (2526W)
Simulation feed forward and feedback
Deluxe controller:
Bathroom controller:
Wireless controller (with transceiver):
Remote Control Cable
Safety Devices
Clearances from combustibles
•Flame failure - Flame Rod
•Boiling protection
•Combustion fan rpm check
•Over current - glass fuse (3 amp)
•Top of heater - 12 inches
•Front of heater - 24 inches
•Sides of heater - 6 inches
•Remaining flame (OHS)
•Thermal fuse
•Automatic frost protection
•Back of heater - 0 inches
•Bottom of heater - 12 inches
Clearances from non-combustibles
Installations within
Manifold Gas Pressure (inches W.C.)
NOx
Warranty
• | Top of heater - 2 inches | • | Back of heater - 0 inches |
• | Front of heater - 24 inches | • | Bottom of heater - 2 inches |
•Sides of heater - 1/2 inches
Clearance to recess box top, bottom, back, and sides: 0 inches
Natural Gas: | min 6” W.C. |
| max 10” W.C. | |
Propane Gas: | min 10.5” W.C. | max 13.5” W.C. | ||
Natural Gas: | high fire 3.4” | W.C. | low fire 0.56” | W.C. |
Propane Gas: | high fire 5.1” | W.C. | low fire 0.88” | W.C. |
Meets California and Texas NOx Emission Rules
Residential only; heat exchanger 10 years*; all other parts 5 years*; labor 1 year; (* 3 years if used as a circulating water heater within a circulation loop, where the water heater is in series with a circulation system and all circulating water flows through the water heater, and where
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
DIMENSIONS
WEIGHT: 46 LBS
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 •