EX22C (RHFE-559FTA)

Type of Appliance

Rinnai Model Number Gas Rate Input (BTU/hour)

Gas Rate Output (BTU/hour)

AFUE Rating

Minimum Gas Supply Pressure

Maximum Gas Supply Pressure

Electrical Connection

Gas Connection

Combustion System

Ignition System

Fan CFM Output

Temperature Settings

Temperature Control

Humidifier Tray Weight

Clearance from Combustibles Noise Level

Warm Air Outlet

EX22C (RHFE-559FTA)

Direct vent wall furnace suitable for homes, apartments, and condominiums, residential or commercial setting; modular/mobile home approved; forced combustion, forced convection

RHFE-559FTA-A-N (Natural gas) RHFE-559FTA-A-P (Propane)

Low - 8,200

Low - 8,200

High - 21,500

High - 20,700

Low - 6,560

Low - 6,560

High - 17,200

High - 16,560

81%

82%

3.5 in (89 mm) W.C.

8 in (203 mm) W.C.

10.5 in (267 mm) W.C

13 in (330 mm) W.C.

AC 120V, 60 Hz, 56 watts

 

1/2 inch NPT

 

Stainless steel Bunsen burners

 

Electronic spark ignition

 

Low: 110.5

High: 162.7

Low (LO): minimum combustion

 

60° - 80° F in 2° increments

 

High (HI): maximum combustion

 

Electronic thermostat

Temperature limiting program to comply with Inside Design Temperature limits

Enameled tray with capacity of 2.1 pints (1000 cc) Approximately 57 lbs (26 kg)

Side: 2 inches (50 mm), Top: 0 inches (0 mm), Front: 40 inches (1 m) 33 - 42 dB(A)

Bottom front louvers

FEATURES

 

 

 

Restart capability:

restarts automatically when ignition or combustion fails

Timer Settings:

starts and turns off the heater at 2 timer settings

Seven-stage modulating gas valve:

provides precise gas flow by operating from one to seven stages

Negative coefficient thermistor:

detects temperature change in 1/2 of a degree

Variable speed inducer motor with

monitors and controls combustion fan and allows the appliance to

pressure switch:

overcome winds of up to 40 mph

Self diagnostic electronics:

continually monitors functions; provides auto shutdown codes; indicates

 

 

when air filter needs cleaning

Quiet operation:

reduces noise through use of swept blades in convection fan; quiet

 

 

expansion / contraction of parts due to temperature changes

 

 

 

 