Tables D: Air Turnover Heating/Cooling Unit with Filtration Performance Information

(For cooling applications, consult factory. Base Unit Weights do not account for inclusion of cooling coils or exclusion of heat exchanger. Additional configurations are available upon request.)

AT-136

CFM

Motor (HP)

Output

Output

Temp. Rise

Base Unit

(MBH)

(MBH)

Range (°F)

Weight

 

 

Minimum

Maximum

(lbs.)

4,500

1.5 (1 motor)

240

450

49 to 93

2,425

9,000

5 (1 motor)

240

450

25 to 46

2,505

12,000

5 (1 motor)

240

450

19 to 35

2,520

AT-148

 

CFM

Motor (HP)

Output

Output

Temp. Rise

Base Unit

 

(MBH)

(MBH)

Range (°F)

Weight

 

 

 

Minimum

Maximum

(lbs.)

 

10,000

5 (1 motor)

240

450

22 to 42

3,455

 

16,000

7.5 (1 motor)

240

750

14 to 43

3,470

AT-154

CFM

Motor (HP)

Output

Output

Temp. Rise

Base Unit

(MBH)

(MBH)

Range (°F)

Weight

 

 

Minimum Maximum

(lbs.)

14,000

5 (1 motor)

240

450

16 to 30

4,080

22,000

7.5 (1 motor)

240

750

10 to 32

4,140

30,000

10 (1 motor)

520

1,000

16 to 31

4,210

30,000

10 (1 motor)

560

1,250

17 to 39

4,420

AT-236

CFM

Motor (HP)

Output

Output

Temp. Rise

Base Unit

(MBH)

(MBH)

Range (°F)

Weight

 

 

Minimum

Maximum

(lbs.)

9,000

1.5 (2 motors)

240

450

25 to 46

4,145

18,000

5 (2 motors)

240

750

12 to 39

4,240

24,000

5 (2 motors)

520

1,000

20 to 39

4,270

AT-242

CFM

Motor (HP)

Output

Output

Temp. Rise

Base Unit

(MBH)

(MBH)

Range (°F)

Weight

 

 

Minimum

Maximum

(lbs.)

21,000

5 (2 motors)

240

750

11 to 33

5,240

31,000

7.5 (2 motors)

520

1,000

16 to 30

5,270

31,000

7.5 (2 motors)

560

1,250

17 to 37

5,445

AT-248

CFM

Motor (HP)

Output

Output

Temp. Rise

Base Unit

(MBH)

(MBH)

Range (°F)

Weight

 

 

Minimum

Maximum

(lbs.)

22,000

5 (2 motors)

240

750

10 to 32

6,190

35,000

7.5 (2 motors)

520

1,000

14 to 26

6,345

45,000

10 (2 motors)

560

1,250

12 to 26

6,575

45,000

10 (2 motors)

560

1,500

12 to 31

6,730

AT-254

CFM

Motor (HP)

Output

Output

Temp. Rise

Base Unit

(MBH)

(MBH)

Range (°F)

Weight

 

 

Minimum

Maximum

(lbs.)

40,000

5 (2 motors)

560

1,750

13 to 41

7,870

60,000

10 (2 motors)

600

2,250

9 to 35

8,310

65,000

15 (2 motors)

600

2,500

9 to 36

8,560

AT-260

CFM

Motor (HP)

Output

Output

Temp. Rise

Base Unit

(MBH)

(MBH)

Range (°F)

Weight

 

 

Minimum

Maximum

(lbs.)

54,000

7.5 (2 motors)

600

3,000

10 to 51

11,070

61,000

10 (2 motors)

720

4,000

11 to 61

11,335

74,000

15 (2 motors)

720

4,000

9 to 50

11,385

AT-272

CFM

Motor (HP)

Output

Output

Temp. Rise

Base Unit

(MBH)

(MBH)

Range (°F)

Weight

 

 

Minimum

Maximum

(lbs.)

62,000

7.5 (2 motors)

600

3,000

9 to 45

12,160

88,000

15 (2 motors)

720

4,500

8 to 47

12,385

100,000

15 (2 motors)

720

4,500

7 to 42

12,515

Installation Code and Annual Inspections:

All installations and service of ROBERTS GORDON® equipment must be performed by a contractor qualified in the installation and ser- vice of equipment sold and supplied by Roberts-Gordon and conform to all requirements set forth in the ROBERTS GORDON® manuals and all applicable governmental authorities pertaining to the installation, service and operation of the equipment. To help facilitate optimum performance and safety, Roberts-Gordon recommends that a qualified contractor annually inspect your ROBERTS GORDON® equipment and perform service where necessary, using only replacement parts sold and supplied by Roberts-Gordon.

Further Information: Applications, engineering and detailed guidance on systems design, installation and equipment performance is available through ROBERTS GORDON® representatives. Please contact us for any further information you may require, including the Installation, Operation and Service Manual.

This product is not for residential use.

This document is intended to assist licensed professionals in the exercise of their professional judgement.

Roberts-Gordon, LLC

 

European Office:

1250 William Street

 

Roberts Gordon Europe Limited

P.O. Box 44

 

Telephone: +44(0)121 506 7700

Buffalo, NY 14240-0044 USA

Fax: +44(0)121 506 7701

Telephone: 716.852.4400

 

Fax: 716.852.0854

 

 

Toll Free: 800.828.7450

 

 

www.rg-inc.com

 

 

© 2007 Roberts-Gordon, LLC

All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form

 

or by any means – graphic, electronic, or mechanical, including photocopying, recording, taping, or information

 

storage and retrieval systems – without written permission of Roberts-Gordon, LLC.

Printed in U.S.A.

CATDSGNA

2M 1107 Orig

Page 8
Image 8
Roberts Gorden AT-248, AT-272, AT-254, AT-260, AT-242, AT-148, AT-154, AT-236, AT-136 manual European Office

AT-248, AT-136, AT-236, AT-154, AT-148 specifications

Roberts Gorden, a prominent manufacturer in the heating and ventilation industry, offers a range of advanced infrared heating solutions designed for commercial and industrial applications. Among its diverse portfolio, the AT series, specifically the AT-148, AT-242, AT-136, AT-254, and AT-260, stands out for its efficiency and innovative features.

The Roberts Gorden AT series is renowned for its advanced radiant heating technology. These heaters operate by directly warming objects and people in the space, rather than just the air. This results in lower energy consumption and enhanced comfort levels, making them ideal for large open areas such as warehouses, manufacturing facilities, and gymnasiums.

One of the key features of these models is their high thermal efficiency. The AT series is designed to offer significant energy savings compared to conventional heating methods. With efficient burner systems and reflective surfaces, these heaters can operate at high efficiency, ensuring that a greater percentage of the fuel used is converted into useful heat.

The AT-148, for instance, is known for its compact design, making it suitable for spaces with limited installation options. Despite its small size, it delivers powerful heating performance. The AT-242 and AT-254 models offer larger heating capacities, making them well-suited for expansive areas that require uniform heat distribution. The AT-260 model stands out for its ability to deliver high output even in challenging environments.

Each model in the AT series is equipped with advanced control systems, allowing for precise temperature regulation and energy management. This feature ensures that users can adapt heating output based on occupancy and specific needs, further enhancing energy efficiency.

Durability is another hallmark of the Roberts Gorden AT series. Constructed with high-quality materials, these heaters are built to withstand harsh industrial environments. Their robust design ensures a long lifespan with minimal maintenance requirements.

In summary, the Roberts Gorden AT-148, AT-242, AT-136, AT-254, and AT-260 models exemplify innovation in radiant heating technology. Featuring high efficiency, advanced control systems, and durable construction, they are engineered to provide optimal heating solutions for a variety of commercial and industrial settings. Whether for large warehouses or specialized industrial applications, the AT series offers a reliable and energy-efficient heating option.