Roksan Audio M series -1 T R O U B L E S H O O T I N G, C a s p i a n Integrated Amplifier

Models: M series -1

1 11
Download 11 pages 59.72 Kb
Page 9
Image 9
KNOW YOUR CASPIAN

KNOW YOUR CASPIAN

When you first power up from the Mains Switch on the rear panel, the amplifier runs a self-test during which all the Indicators pulse twice. When the self-test is complete the amplifier goes into Standby and the MODE Indicator glows GREEN.

During Standby, the power stage of the amplifier shuts down to reduce power consumption and heat.

If the amplifier overheats through overload or lack of ventilation, the Caspian will revert to Standby until it has cooled down. If it subsequently overheats the amplifier will revert to Standby and stays in Standby. You will then have to wait until the amplifier cools down fully and will have to bring it out of Standby manually.

In the unlikely event of an internal fault such as a power supply failure, the MODE Indicator light will flash GREEN and the amplifier will shut down. The amplifier will then run a self-test. If all is well, the amplifier will revert to Standby. If the fault persists, the Indicator light will continue to flash.

 

T R O U B L E S H O O T I N G

C a s p i a n Integrated Amplifier

 

 

 

 

 

 

 

If you suspect that your ROKSAN Caspian Integrated Amplifier is not operating properly, you should check all the connections carefully. Pay particular attention to speaker phasing and channel connections. Phono plugs should be fully inserted- a frequent cause of problems is that Phono plug surrounds do not make proper contact. Below are some commonly encountered problems with suggestions for possible cure. The list is not exhaustive: If you have any unresolved problems, please consult your appointed ROKSAN dealer or distributor.

SYMPTOM

LIKELY CAUSE

SUGGESTED REMEDY

No power

AC Mains lead not inserted properly

Ensure AC Mains lead is fully inserted

 

Unit not switched on at rear panel

Switch unit on at rear panel

No output on one or both

Amplifier in stand-by mode (MODE light

Press MODE button to set amplifier in

channels

GREEN)

operational mode (MODE light RED)

 

Missing or bad input signal connection

Check all input connections

 

Incorrect speaker connection

Check speaker output connections on

 

 

rear panel

 

Wrong input selected

Select correct input, ascertain source is

 

 

working

 

Tape Monitor selected

Deselect Tape Monitor

 

Over heating

Allow amplifier to cool, increase

Very low sound output

 

ventillation or use at lower volume

 

Amplifier set in MUTE position

Deselect MUTE (check volume setting

Poor speaker imaging, lack

 

first)

of Bass output

Loudspeakers connected out of phase

Check polarity of speaker connections

 

 

(especially important if Multi-wiring,

 

 

Multi-Amping)

 

 

 

Hum from speakers

Incorrect Grounding

Check Mains polarity and grounding on

 

 

all connected equipment