Recording
45
Overview Getting Ready Recording Playback File Operation Computer Appendix
Setting the input level1. From the main screen, press the [ ] button.
The REC indicator will blink, and the R-26 will enter recording-standby mode.
2. Produce sound on the source you’re recording.
The level meter will move according to the loudness of the sound being input to the R-26.
3. Turn the [INPUT 1] knob and [INPUT 2] knob to adjust the input level.
Adjust the level until it is as high as you can get it without causing the PEAK indicator, or PEAK in
the level meter, to light.
The recording sources adjusted by each knob will depend on the combination of REC MODE and
REC SOURCE you’ve selected.
REC MODE REC SOURCE [INPUT 1] knob [INPUT 2] knob
1 CHANNEL ANALOG (MONO) ANALOG IN 1/L –
2 CHANNEL
INTERNAL INTERNAL MIC –
ANALOG ANALOG IN 1/L, 2/R –
ANALOG (MONO) ANALOG IN 1/L ANALOG IN 2/R
PLUG-IN PLUG IN MIC –
4 CHANNEL
XY + OMNI INTERNAL MIC (shared by XY
and OMNI) –
INTERNAL + ANALOG INTERNAL MIC ANALOG IN 1/L, 2/R
ANALOG + PLUG-IN ANALOG IN 1/L, 2/R PLUG IN MIC
XY + PLUG-IN XY MIC PLUG IN MIC
6 CHANNEL
XY + OMNI + INT INTERNAL MIC (shared by XY
and OMNI) –
XY + OMNI + ANALOG INTERNAL MIC (shared by XY
and OMNI) ANALOG IN 1/L, 2/R
XY + ANALOG + P-IN INTERNAL MIC ANALOG IN 1/L, 2/R
How input sensitivity and input level are related
Input sensitivity adjusts the loudness of the input signal being received as the
recording source. Input level is an additional ne adjustment applied to the signal
after it’s been adjusted by input sensitivity, in order to optimize it for recording.
* Adjust the input sensitivity in the following situations.
• The level meters don’t move suciently even when the knob is in the maximum
position.