92
Material
Problem Check/Solution Page
Tones Are Altered
Did you call up a Live Set?
When a Live Set is called up, the current Tone, eect, and other settings are disabled,
and the selected Live Set goes into eect. Resave required settings to a Live Set.
p. 44
Did you press the ONE TOUCH PIANO button or the ONE TOUCH E. PIANO button?
When the ONE TOUCH PIANO button or the ONE TOUCH E. PIANO button is pressed,
the current Tone, eect, and other settings are disabled, and settings for use in piano
performances go into eect. Resave required settings to a Live Set.
p. 26
Is the Tone Control function assigned to the LAYER LEVEL slider?
Check the “Slider Assign” settings of Control in Edit mode. p. 73
When a mono connection is used, the tone quality can vary depending on the tone
selected and the register in which it is used.
For optimal listening quality, connecting in stereo is recommended.
Tone Doesn’t Change/Keyboard Not
Switching to Split
Is the “MIDI” indicator lit?
When the “MIDI” indicator is lit, the external sound generator is controlled. To change
the RD-700NX’s Tones and make settings in Keyboard mode, set the “MIDI” indicator
to OFF.
p. 59
Is the Layer containing the Tone you want to change set to ON? p. 30
Rhythm Not Sounding Could a song be playing? p. 38
Eects Not Applied/Eects Sound
Wrong
Is a TW-Organ 1–10 Tone selected?
Eects are applied dierently to the Tone Wheel than they are with other eects.
When Tone Wheel is selected for multiple Parts, it is applied to all the Parts.
Are the MFX1 and MFX2 set to OFF? p. 41
In some cases where the delay timing selected in the DELAY settings in Eects is set to
a note value, the delay sound may not be heard. Either adjust the tempo or change the
numerical value of the delay timing.
No Modulation When Modulation Lever
is Moved
Could you have selected an organ tone?
For some of the organ tones, the modulation lever cannot be used to apply a
modulation eect. For such tones, the modulation lever is used to switch the rotary
eect between slow and fast.
p. 42
Could you have selected the SuperNatural E. Piano sound?
You can’t apply pitch bend or modulation eects to the SuperNatural E. Piano sound.
Can’t obtain pitch bend eect when the
pitch bend lever is moved
Is the Tone Wheel screen appearing in the display?
The pitch bend eect cannot be applied with the pitch bend lever while the Tone
Wheel screen is in the display. In this case, the pitch bend lever functions as a slow/fast
switch for the Rotary eect.
p. 42
Sounds Come From Left or Right Each
Time Key is Pressed (Panned)
In some Tones, the settings are such that sounds randomly play from the left or right
side (are panned) each time the keys are pressed. These settings cannot be changed.
Sound is Distorted
Sounds can be distorted due to equalizer, multi-eect, and Part volume settings.
Adjust the following settings.
LAYER LEVEL sliders
System Master Volume settings
Equalizer Input Gain settings
p. 31
p. 67
p. 35
Is a distortion-type eect being applied to the sound?
Cannot Select the Tone Wheel Screen The screen is displayed by selecting a Organ Tone (TW-Organ 1–10) for any layer in the
Live Set screen, and then pressing Cursor the [ ] button. p. 42
Key Range Settings Not Eective Is the [SPLIT] button set to OFF?
Key Range goes into eect when the [SPLIT] button set to ON.
p. 62
p. 56