Appendices
S-1608/S-0816 Digital Snake Owner’s Manual 73
Specifications: S-0816 FOH UNIT *1: When a REAC Splitter S-4000-SP or a switching hub is used in-line with REAC cables, the network latency will increase by the amount
of processing delay introduced by the splitting device itself. The actual delay is dependant upon the specifications of the splitting
device, though the maximum delay amount for a single splitting device should be about 200 microseconds.
* 0 dBu = 0.775 V rms
* In the interest of product improvement, the specifications and/or appearance of this unit accessories are subject to change without prior
notice.
Number of Channels 8 in 16 out
AD Conversion Sample Rate: 96.0 kHz
Signal Processing: 24 bits
DA Conversion Sample Rate: 96.0 kHz
Signal Processing: 24 bits
Frequency Response -2 dB / +0 dB (@ +4 dBu, 20 Hz to 20 kHz)
Total Harmonic Distortion + Noise 0.05 % or less (Pad: On, Input Gain: +4 dBu, 22 Hz to 20 kHz)
Dynamic Range 110 dB
Cross Talk -80 dB or less (Input Gain: +4 dBu, typ.)
Nominal Input Level -65 to -10 dBu (PAD: Off)
-45 to +10 dBu (PAD: On)
(1 dB step, Max. +28 dBu)
PAD 20 dB On/Off
Input Impedance 14 k ohms
Nominal Output Level +4 dBu, Max. +22 dBu
Output Impedance 600 ohms
Recommended Load Impedance 10 k ohms or greater
Residual Noise Level (IHF-A, typ.) -80 dBu or less
Equivalent Input Noise Level (E.I.N.) -124 dB
Network Latency 375 microseconds when using REAC cable only *1
(AD
REAC
DA Latency: about 1.2 ms)
Connectors Input x 16 (XLR type, balanced, phantom power)
Output x 8 (XLR type, balanced)
DIGITAL OUT connector x 1 (Optical type)
REAC Connector x 1 (RJ-45 EtherCon type)
Remote Connector x 1 (RS-232C, DB-9 type)
Indicators POWER Indicator x 1, REAC Indicator x 1, REMOTE Indicator x 1,
MUTE ALL OUTPUTS Indicator x 1
Power Supply AC 115 V, AC 117 V, AC 220 V, AC 230 V, AC 240V (50/60 Hz)
Power Consumption 45 W
Phantom Power +48 V / 14 mA (each input, remote controlled)
Dimensions 401 (W) x 135.0 (D) x 177.0 (H) mm
15-13/16 (W) x 5-3/8 (D) x 7 (H) inches
Weight 5.5 kg
12 lbs 3 oz
Operation Temperature 0 to +40 degrees Celsius
+32 to +104 degrees Fahrenheit
Accessories Power Cord x 1, REAC Connector Covers x 1, Ferrite Core x 1, Rubber Foot x 4,
Rack Mount Kit x 1, Owner’s Manual
Options REAC Splitter: S-4000-SP
Cat5e Ethernet Crossover Cable with Neutrik(R) EtherCon(R) Plug: SC-W100S (100 m)
S-1608_e.book 73 ページ 2007年4月23日 月曜日 午後12時57分