131
Chapter 8: Specifications
8-6 Specifications
*1
• Media type: Roland SV-G-1270G, print travel: 1 m
• Preset temperature for the print heater: 40˚C
• Temperature: 20˚C, humidity: 50%
*2
• Media type: Roland PET-G-1050, print travel: 1 m
*3
Not assured when the print heater is used.
*4
The following conditions must be satisfied:
• Media type: 3M Scotchcal Mastercut Film
• Roll media must be loaded on the shaft
• The required length for cutting must be pulled out from the roll.
• Side margins: 25 mm or more for both the left and right margins
• Front margin: 35 mm or more
• Excluding stretching/contraction of the media
Range for assured repetition accuracy
• For media with a width exceeding 610 mm: Length 4,000 mm
• For media with a width of 610 mm or less: Length 8,000 mm
*5
• Provided that media length is under 3000 mm
• Temperature: 25˚C
• Excluding possible shift caused by expansion/contraction of the media and/or by reloading the media
*6
• Media type: Roland SV-G-1270G
• No lamination
• Data size: 3,000 mm in the media-feed direction, 1,000 mm in the carriage-movement direction
• When reloading the media, at the menu, select [BASE-ALIGN] to automatically detect crop marks.
• The required length for cutting must be pulled out from the roll.
• Temperature: 25˚C
• Excludes the effects of slanted movement and of expansion and contraction of the media
*7
The print heater temperature may not reach the preset temperature depending on ambient conditions or the width of the media.
Unevenness in temperature may be larger depending on ambient conditions or the width of the media.
*8
Operating environment
80
55
35
15 27 32
Humidity
20
(%)
°C (°F
)
(
no condensation)
Temperature
(
59
)(
89.6
)(
80.6
)(
68
)
0
Use in an operating environ-
ment with this range.