OPERATION INSTRUCTIONS

Pre-Start Procedures:

1.Inspect the compressor for any damaged components. Do not operate if compressor is damaged.

2.Check oil level in the compressor pump (See “Checking Oil Level”).

3.Verify that the tanks have been drained and are clear of any moisture or dirt (See “Draining Tank”).

4.Verify that the air filter is securely in place (See “Air Filter Installation”).

Start-Up Procedures:

1.Verify that the On/Off switch is in the Off position.

2.Verify that the tank air pressure is at 0 PSI.

3.Attach the air hose to the discharge line.

4.Plug the unit into a properly grounded outlet.

5.Pull out the On/Off switch to On. The compressor will automatically cycle on and off to keep the tank pressure maintained .

6.Adjust the pressure regulator to the proper pressure setting required for the air tool.

Shut-Off Procedures:

1. Push in the On/Off switch to the Off position.

GENERAL MAINTENANCE

Service and Maintenance:

Prior to performing service and maintenance to the compressor, always disconnect all accessories and attachments from the unit and disconnect the compressor from the electrical source. When replacing parts, only use Genuine BOSTITCH replacement parts.

Checking the pump Oil Level:

1.Verify that the compressor is turned off and on a level surface.

2.Remove oil fill plug - Add until oil reaches “MAX” oil notch in oil fill plug.