FRONT PANEL DESCRIPTION
Note: Channel One descriptions are identical to Channel Two
PHANTOM POWER +48V
Turns on the internal 48 volt power supply for using phantom powered microphones. It should be left off when not in use.
30 dB Pad
When pressed in, the rear panel XLR input is attenuated by 30 dB. It does not switch the instrument input.
INSTRUMENT INPUT
1/4" input jack for plugging a guitar, electric bass, or other instrument direct into the preamp. When this jack is used, the XLR input on the rear panel is disconnected.
GAIN
Adjusts how much actual gain the preamp has. This is similar to a "trim" control on some mixers and is different from volume. With the gain set high the input may be distorted. For best signal to noise ratio this control should be set as high as possible without distortion, (unless distortion is desired).
VOLUME
Sets the output level as desired, for best signal to noise ratio it should be set in the middle of its range or higher.
OUTPUT LEVEL METERS
Each channel of the RP220 has five LED level meters, the last one being red indicating overload.
Dual Tube Microphone Preamp
| Channel One |
| Channel Two |
| ||
| GAIN | VOLUME | GAIN |
| VOLUME |
|
| NORM |
| NORM |
|
|
|
+48V |
| +48V |
|
|
| |
|
|
|
| PWR | ||
| INPUT |
| INPUT |
|
| |
| +38 dB +65 | - OO dB 0 | +38 dB | +65 | - OO dB 0 | RP220 |
PHANTOM INPUT |
| PHANTOM INPUT |
|
|
| |
POWER PAD |
| POWER PAD |
|
|
|
REAR PANEL DESCRIPTION
Note: Channel One descriptions are identical to Channel Two
INPUT
Standard XLR type balanced inputs, pin 2 is hot, for Mic or
OUTPUT JACKS
1/4" phone connectors or balanced XLRs used for connection to your line inputs on your load (e.g., DAT, Amp. or mixer).
30 dB Pad
This switch changes the level of the Output XLR jack only. When in, it attenuates the output level by 30 dB.
PHASE REVERSE
When pressed in, reverses the phase of the output signal 180 degrees from the input signal.
|
| SERIAL NUMBER |
|
|
|
|
|
| MODEL RP220 | 220- |
|
|
|
|
|
| CAUTION |
|
| CHANNEL |
| CHANNEL | |
120 VAC |
|
|
| TWO |
| ONE |
|
50/60 Hz 15 VA | RISK OF ELECTRIC SHOCK |
| OUTPUT | INPUT |
| OUTPUT | INPUT |
| DO NOT OPEN |
|
| ||||
| WARNING: DO NOT EXPOSE THIS EQUIPMENT TO RAIN | NORM | NORM |
| NORM | NORM | |
|
|
| OUTPUT |
|
| ||
MADE IN U.S.A. | OR MOISTURE. | OUTPUT | REV | REV | |||
|
|
|
|
|
|
| |
| CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT |
|
|
|
|
| |
| NOT REMOVE BACK. NO USER SERVICABLE PARTS INSIDE. REFER | PHASE OUTPUT |
| PHASE OUTPUT | |||
| SERVICING TO QUALIFIED SERVICE PERSONNEL. |
|
| ||||
|
|
| LEVEL |
|
| LEVEL | |
| RISQUE DE CHOC - NE PAS ENLEVER |
|
|
|
| ||
NRTL /C |
|
|
|
|
|
| |
|
|
|
|
|
|
|
SPECIFICATIONS |
|
Frequency Response | 20Hz - 40kHz, +/- 3dB Mic/Line |
| 5Hz - 40kHz inst. |
Input Impedance | 600 ohm balanced XLR |
| 1M ohm Instrument |
THD | 0.1% typical |
S\N Ratio | >107 dB |
Max Gain | 48dB Inst or line, 70dB XLR |
Indicators | 2 - LEDs (Phantom Power) |
| 5 - Level LEDs, 4 green 1 red |
Input/Output jacks | XLR balanced and 1/4" |
Dimensions | 3.5" X 6" X 19" (89mm X 162mm X 482mm) |
Power | 120VAC (230VAC) 15VA |
2 | 3 |