Rolls RP220 owner manual Front Panel Description, Rear Panel Description, Specifications

Models: RP220

1 4
Download 4 pages 37.17 Kb
Page 3
Image 3
FRONT PANEL DESCRIPTION

FRONT PANEL DESCRIPTION

Note: Channel One descriptions are identical to Channel Two

PHANTOM POWER +48V

Turns on the internal 48 volt power supply for using phantom powered microphones. It should be left off when not in use.

30 dB Pad

When pressed in, the rear panel XLR input is attenuated by 30 dB. It does not switch the instrument input.

INSTRUMENT INPUT

1/4" input jack for plugging a guitar, electric bass, or other instrument direct into the preamp. When this jack is used, the XLR input on the rear panel is disconnected.

GAIN

Adjusts how much actual gain the preamp has. This is similar to a "trim" control on some mixers and is different from volume. With the gain set high the input may be distorted. For best signal to noise ratio this control should be set as high as possible without distortion, (unless distortion is desired).

VOLUME

Sets the output level as desired, for best signal to noise ratio it should be set in the middle of its range or higher.

OUTPUT LEVEL METERS

Each channel of the RP220 has five LED level meters, the last one being red indicating overload.

Dual Tube Microphone Preamp

 

Channel One

 

Channel Two

 

 

GAIN

VOLUME

GAIN

 

VOLUME

 

 

NORM

 

NORM

 

 

 

+48V

-30dBINSTRUMENT

 

+48V

 

 

 

 

 

-30dBINSTRUMENT

 

 

PWR

 

INPUT

 

INPUT

 

 

 

+38 dB +65

- OO dB 0

+38 dB

+65

- OO dB 0

RP220

PHANTOM INPUT

 

PHANTOM INPUT

 

 

 

POWER PAD

 

POWER PAD

 

 

 

REAR PANEL DESCRIPTION

Note: Channel One descriptions are identical to Channel Two

INPUT

Standard XLR type balanced inputs, pin 2 is hot, for Mic or line-level audio sources. (e.g., instrument, microphone or mixer).

OUTPUT JACKS

1/4" phone connectors or balanced XLRs used for connection to your line inputs on your load (e.g., DAT, Amp. or mixer).

30 dB Pad

This switch changes the level of the Output XLR jack only. When in, it attenuates the output level by 30 dB.

PHASE REVERSE

When pressed in, reverses the phase of the output signal 180 degrees from the input signal.

 

 

SERIAL NUMBER

 

 

 

 

 

 

MODEL RP220

220-

 

 

 

 

 

 

CAUTION

 

 

CHANNEL

 

CHANNEL

120 VAC

 

 

 

TWO

 

ONE

 

50/60 Hz 15 VA

RISK OF ELECTRIC SHOCK

 

OUTPUT

INPUT

 

OUTPUT

INPUT

 

DO NOT OPEN

 

 

 

WARNING: DO NOT EXPOSE THIS EQUIPMENT TO RAIN

NORM

NORM

 

NORM

NORM

 

 

 

OUTPUT

 

 

MADE IN U.S.A.

OR MOISTURE.

OUTPUT

REV

-30dB

REV

-30dB

 

 

 

 

 

 

 

 

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT

 

 

 

 

 

 

NOT REMOVE BACK. NO USER SERVICABLE PARTS INSIDE. REFER

PHASE OUTPUT

 

PHASE OUTPUT

 

SERVICING TO QUALIFIED SERVICE PERSONNEL.

 

 

 

 

 

LEVEL

 

 

LEVEL

 

RISQUE DE CHOC - NE PAS ENLEVER

 

 

 

 

NRTL /C

 

 

 

 

 

 

 

 

 

 

 

 

 

SPECIFICATIONS

 

Frequency Response

20Hz - 40kHz, +/- 3dB Mic/Line

 

5Hz - 40kHz inst.

Input Impedance

600 ohm balanced XLR

 

1M ohm Instrument

THD

0.1% typical

S\N Ratio

>107 dB

Max Gain

48dB Inst or line, 70dB XLR

Indicators

2 - LEDs (Phantom Power)

 

5 - Level LEDs, 4 green 1 red

Input/Output jacks

XLR balanced and 1/4"

Dimensions

3.5" X 6" X 19" (89mm X 162mm X 482mm)

Power

120VAC (230VAC) 15VA

2

3