Electric Dryer
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
DOOR CLEARANCE DIMENSIONS
RES7646JREX4625E
RES7646KREX4634J
RES7648EREX4634K
RES7648JREX4635E
RES7648KREX5634J
REX3614JREX5634K
REX3614KREX5635E REX3615E
terminal block cover
power supply cord/cable opening
Electrical: A
Exhaust venting: Exhaust your dryer to the outside.
dryer exhaust vent
28" max. | 29" |
|
7"
must be at least 12 inches from the ground or any object that may be in the path of the exhaust.
*from floor with dryer feet extended 1 inch
Large
RECESSED AREA AND CLOSET INSTALLATION
| Recommended/Minimum | Closet confined area | |||||||
|
|
|
|
| |||||
| Back | Sides | Top | Front | |||||
Recessed | 5"/0" | 1"/0" | 18"/18" | — | If a closet door is installed: The minimum unobstructed air | ||||
|
|
|
|
| openings are required. Louvered doors with equivalent air | ||||
Closet | 5"/4" | 1"/0" | 18"/18" | 1"/1" | |||||
openings are acceptable. |
| ||||||||
| front view |
|
|
| |||||
|
|
| front view |
|
| side view | |||
|
|
|
|
|
| 3" |
|
| 48 sq. in.** | closet | 14" |
|
| max. | |
| Recessed | door |
|
18" |
|
| |
area |
|
| |
|
|
| |
| 24 sq. in.** |
| 4"*** |
|
|
| |
|
| 3" |
|
0" * | 0" * | 1" |
|
*Wall, door and floor molding may require | ** Minimum top and bottom air openings for closet door. |
additional spacing. | *** External exhaust elbow requires additional space. |
|
EXHAUST VENTING
Small
Preferred
4" |
|
| 4" |
| |||
|
| ||
|
|
|
|
| Maximum length of 4" | |
| diameter metal vent | |
|
|
|
Number of | Rigid | Flexible |
90° elbows |
| (fully extended) |
|
|
|
0 | 64 ft. | 36 ft. |
|
|
|
1 | 54 ft. | 31 ft. |
|
|
|
2 | 44 ft. | 27 ft. |
|
|
|
3 | 35 ft. | 25 ft. |
|
|
|
4 | 27 ft. | 23 ft. |
|
|
|
Acceptable
| Maximum length of 4" | |
| diameter metal vent | |
|
|
|
Number of | Rigid | Flexible |
90° elbows |
| (fully extended) |
|
|
|
0 | 58 ft. | 28 ft. |
|
|
|
1 | 48 ft. | 23 ft. |
|
|
|
2 | 38 ft. | 19 ft. |
|
|
|
3 | 29 ft. | 17 ft. |
|
|
|
4 | 21 ft. | 15 ft. |
|
|
|
Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Avoid making 90° turns.
When using elbows or making turns, allow as much room as possible. Bend flexible metal vent gradually to avoid kinking.
Determine vent length
1.See the exhaust vent length chart that matches your type hood for the maximum vent lengths you can use.
Do not use vent runs longer than specified in exhaust vent length charts.
2.Determine the number of elbows you will need.
3.In the column listing the type of metal vent you are using (rigid or flexible), find the maximum length of metal vent on the same line as the number of elbows.
The maximum length using a 2" x 6" rectangular vent with 2 elbows and a
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation | Ref. 3397618 |
Instructions packed with product. Specifications subject to change without notice. |