Roper dimensions Electric Dryer, Product Model Numbers, RES7745RREX6634R, Overall Dimensions

Models: RED4400S RES6745R REX3514R

1 1
Download 1 pages 23.28 Kb
Page 1
Image 1
Electric Dryer

®

Electric Dryer

PRODUCT MODEL NUMBERS

RED4100SREX3514P

RED4400SREX3514R

RES6745PREX3614P

RES6745RREX5634R

RES7745RREX6634R

Electrical: A four-wire or three-wire, single phase, 120/240-volt, 60 Hz, AC-only, electrical supply (or 120/208-volt electrical supply, if specified on the serial/rating plate) is required on a separate 30 amp circuit, fused on both sides of the line. Use 10 gauge solid copper wire. A time-delay fuse or circuit breaker is recommended.

OVERALL DIMENSIONS

 

15¼"

 

22 ¾"

 

43 ³⁄₈"

(57.8 cm)

43 ³⁄₈"

(38.74 cm)

(110 cm)

 

(110 cm)

 

*26"

 

*27 ¾"

 

(66 cm)

 

(70.5 cm)

 

29"

 

 

29"

(73.66 cm)

 

 

(73.66 cm)

A

 

 

B

Exhaust venting: Exhaust your dryer to the outside. Four-inch diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do not use plastic or metal foil vent. Exhaust outlet hood must be at least 12 inches from the ground or any object that may be in the path of the exhaust.

43 ³⁄₈" PRODUCT MODEL NUMBERS (110 cm)

*27 ¾"

(70.5 cm)

22 ¾"

(57.8 cm) 43 ³⁄₈"

(110 cm)

*27 ¾"

(70.5 cm)

29"

(73.66 cm)

RED4100SREX3514P 13 ¾" (34.9 cm)

29"

(73.66 cm)

C

D

A. Small opening side-swing door

* Most installations require a

B. Large opening side-swing door

minimum 5 ¹⁄₂" (14 cm)

C. Wide opening side-swing door

clearance behind the dryer for

the exhaust vent with elbow.

D. Wide opening hamper door

 

RECESSED AREA AND CLOSET INSTALLATION

EXHAUST VENTING

 

 

 

 

14" max.

48 in. 2

 

 

 

 

(35.6cm)

18"

 

 

 

 

 

(310 cm2 )

 

 

 

 

 

 

(45.7 cm)

 

 

 

 

 

 

 

 

 

 

 

 

24 in.2

 

 

 

 

 

 

(155 cm2 )

0"*

29"

0"*

0"*

27¾"

5½"

 

(0 cm)

(73.66 cm)

(0 cm)

(0 cm)

(70.5 cm)

(14 cm)

 

A

 

 

B

 

C

*Additional spacing recommended

RES7745RREX6634R 3" (7.6 cm)

For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent

3" air openings are acceptable.

(7.6 cm)

A. Recessed area

B. Side view - closet or confined area C. Closet door with vents

Number of

Type of

Box or

Angled

90° turns

vent

Louvered

hoods

or elbows

 

hoods

 

 

 

 

 

0

Rigid metal

64 ft (20 m)

58 ft (17.7 m)

 

Flexible metal

36 ft (11 m)

28 ft (8.5 m)

 

 

 

 

1

Rigid metal

54 ft (16.5 m)

48 ft (14.6 m)

 

Flexible metal

31 ft (9.4 m)

23 ft (7 m)

 

 

 

 

2

Rigid metal

44 ft (13.4 m)

38 ft (11.6 m)

 

Flexible metal

27 ft (8.2 m)

19 ft (5.8 m)

 

 

 

 

3

Rigid metal

35 ft (10.7 m)

29 ft (8.8 m)

 

Flexible metal

25 ft (7.6 m)

17 ft (5.2 m)

 

 

 

 

4

Rigid metal

27 ft (8.2 m)

21 ft (6.4 m)

 

Flexible metal

23 ft (7 m)

15 ft (4.6 m)

NOTE: Side and bottom exhaust installations have a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart.

Recommended hood styles

Angled hood style is

B

acceptable.

 

4"

A

(10.2 cm)

 

4"

2.5"

(6.4 cm)

(10.2 cm)

 

4"

 

(10.2 cm)

 

A. Louvered hood style

 

B. Box hood style

 

Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Avoid making 90° turns.

Do not use vent runs longer than specified in vent length chart. Determine the number of elbows you will need.

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation

Ref. 8577187

Instructions packed with product. Specifications subject to change without notice.

08-03-06

Page 1
Image 1