Electric Dryer
PRODUCT MODEL NUMBERS
RED4100SREX3514P
RED4400SREX3514R
RES6745PREX3614P
RES6745RREX5634R
RES7745RREX6634R
Electrical: A
OVERALL DIMENSIONS
| 15¼" |
| 22 ¾" |
| 43 ³⁄₈" | (57.8 cm) | |
43 ³⁄₈" | (38.74 cm) | ||
(110 cm) |
| (110 cm) |
|
*26" |
| *27 ¾" |
|
(66 cm) |
| (70.5 cm) |
|
29" |
|
| 29" |
(73.66 cm) |
|
| (73.66 cm) |
A |
|
| B |
Exhaust venting: Exhaust your dryer to the outside.
43 ³⁄₈" (110 cm)
*27 ¾"
(70.5 cm)
22 ¾"
(57.8 cm) 43 ³⁄₈"
(110 cm)
*27 ¾"
(70.5 cm)
29"
(73.66 cm)
13 ¾" (34.9 cm)
29"
(73.66 cm)
C | D | |
A. Small opening | * Most installations require a | |
B. Large opening | minimum 5 ¹⁄₂" (14 cm) | |
C. Wide opening | clearance behind the dryer for | |
the exhaust vent with elbow. | ||
D. Wide opening hamper door | ||
|
RECESSED AREA AND CLOSET INSTALLATION
EXHAUST VENTING
|
|
|
| 14" max. | 48 in. 2 | |
|
|
|
| (35.6cm) | ||
18" |
|
|
|
|
| (310 cm2 ) |
|
|
|
|
|
| |
(45.7 cm) |
|
|
|
|
|
|
|
|
|
|
|
| 24 in.2 |
|
|
|
|
|
| (155 cm2 ) |
0"* | 29" | 0"* | 0"* | 27¾" | 5½" |
|
(0 cm) | (73.66 cm) | (0 cm) | (0 cm) | (70.5 cm) | (14 cm) | |
| A |
|
| B |
| C |
*Additional spacing recommended
3" (7.6 cm)
For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent
3" air openings are acceptable.
(7.6 cm)
A. Recessed area
B. Side view - closet or confined area C. Closet door with vents
Number of | Type of | Box or | Angled |
90° turns | vent | Louvered | hoods |
or elbows |
| hoods |
|
|
|
|
|
0 | Rigid metal | 64 ft (20 m) | 58 ft (17.7 m) |
| Flexible metal | 36 ft (11 m) | 28 ft (8.5 m) |
|
|
|
|
1 | Rigid metal | 54 ft (16.5 m) | 48 ft (14.6 m) |
| Flexible metal | 31 ft (9.4 m) | 23 ft (7 m) |
|
|
|
|
2 | Rigid metal | 44 ft (13.4 m) | 38 ft (11.6 m) |
| Flexible metal | 27 ft (8.2 m) | 19 ft (5.8 m) |
|
|
|
|
3 | Rigid metal | 35 ft (10.7 m) | 29 ft (8.8 m) |
| Flexible metal | 25 ft (7.6 m) | 17 ft (5.2 m) |
|
|
|
|
4 | Rigid metal | 27 ft (8.2 m) | 21 ft (6.4 m) |
| Flexible metal | 23 ft (7 m) | 15 ft (4.6 m) |
NOTE: Side and bottom exhaust installations have a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart.
Recommended hood styles | Angled hood style is |
B | acceptable. |
| 4" |
A | (10.2 cm) |
| |
4" | 2.5" |
(6.4 cm) | |
(10.2 cm) |
|
4" |
|
(10.2 cm) |
|
A. Louvered hood style |
|
B. Box hood style |
|
Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Avoid making 90° turns.
Do not use vent runs longer than specified in vent length chart. Determine the number of elbows you will need.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation | Ref. 8577187 |
Instructions packed with product. Specifications subject to change without notice. |