7. USB Communication Port

Power Protection UPS RU103

User Manual

 

 

 

7. USB Communication Port

The built-in USB port connects to your computer. The PowerGuard Smart monitoring and shutdown software provided can automatically save your files and shut down your computer in the event of a prolonged power outage. The software also provides information regarding the status of your utility power line

information. Other brand(s) of battery please contact Rosewill.com.

Battery Name

Recycling inside the USA

 

 

Vision Battery

1-877-730-2877

 

 

First Power Battery

1-877-730-2877

 

 

BB Battery

1-800-278-8599

 

 

Installing software

Follow the on-screen instructions.

If autoplay is not enabled on the computer, please follow instructions below: Double-click on My Computer on the desktop.

Double-click on the CD-ROM drive icon and follow the on-screen

instructions.

8.Data /Phone/Fax Protection Connectors

9.“Surge Only” Outlets

Four Nema 5-15R output receptacles that will provide surge and spike

protection only

10.“Battery & Surge” Outlets

Four Nema 5-15R output receptacles that will provide both battery backup and

surge protection.

11.AC Input Power Cord

Plug the AC power cord into your power source

12.Coax in :

TV/TNT/Satellite reception protection

13.Circuit Breaker (re-settable)

The button will protrude when the overload condition occurs. If the button

SPECIFICATIONS

Model

RU-103

 

 

Capacity

1500 VA / 900W

 

Nominal Input Voltage

120 Vac

 

 

Nominal Output Voltage

120 Vac

 

 

Automatic Voltage

108-130Vac(±3%)

Regulation (AVR)

 

Frequency

50 / 60 Hz auto sensing

 

 

Outlets

8 Outlets (4 Battery Backup & Surge Protection;

4 Surge Protection only)

 

Lighting / Surge Protection

320 Joules

 

 

Transfer time to Battery/AC

2-6ms typical

 

 

Battery Type

Maintenance free lead-acid battery

 

 

Battery Specification

(2)* 12V 9 Ah

 

 

Typical Backup Time

4-7 Minutes

 

 

LAN / Phone / Fax Protection

RJ11/45

 

 

Short Circuit Protection

Circuit Breaker

 

 

Communication Port

USB

 

 

Operation Temperature

0°C–40°C

 

 

Operation Relative Humidity

0 to 95% non-condensing

 

 

Storage Temperature

-15°C–50°C

 

 

Net Weight

29.3 lb

 

 

Dimensions (HxWxD)

10.8 x 3.4 x 16.1 IN

Specifications may change without prior notice.

protrudes, disconnect some non-essential equipment and reset the circuit

breaker by pushing the button inward.

14.Coax out:

TV/TNT/Satellite reception protection

INDICATOR TABLE

Status Indicators

The UPS provides both visual and audible status indicators. Visual indicators consist of three LEDs to represent the following conditions:

On utility power operation

On battery power operation

UPS fault/alarm

LED and Alarm Indicator Table

UPS Status

Green

Red LED

Yellow

Alarm

 

 

LED

 

LED

 

Self-test

 

Blink 1

 

B1

AC mode

Normal

On

X

X

X

( on utility)

 

 

 

 

 

Self Low

On

Blink2

X

B5

 

 

battery

 

 

 

 

 

overload

On

Blink2

X

B2

 

 

 

 

 

 

DC mode

Normal

X

X

On

B1

( on battery)

Low

X

X

Blink2

B3

 

battery

 

 

 

 

 

Overload

X

Blink2

On

B2

Short/Fault

mode

X

On

X

On

Over-Bat/Bat Fault

X

Blink2

X

B4

* Blink 1

: ON 0.5 seconds / OFF 1 seconds

* Blink 2

: ON 0.25 seconds / OFF 0.25 seconds

* B1: 1 beep / 5 seconds: ON 0.25 seconds / OFF 4.75 seconds

* B2: 1 beep / 0.5 seconds :ON 0.25 seconds / OFF 0.25 seconds

* B3

: 2 beeps / 5 seconds: ON 0.25 seconds / OFF 0.25 seconds 2 times, 4 seconds OFF

* B4

: 3 beeps / 5 seconds: ON 0.25 seconds / OFF 0.25 seconds 3 times, 3.5 seconds OFF

TROUBLESHOOTING

Symptom Possible Cause

UPS will not turn The UPS is not

onconnected to the power source. Circuit Breaker has tripped.

UPS is making a

The “Battery Backup &

continuous

Surge Protection”

sound and the

outlets are overload.

“Overload”

 

indicator is on

 

UPS does not

The UPS battery is

provide

discharged due to a

expected

power outage and has

not recharged.

runtime

Back-UPS is heavily

 

 

loaded.

 

 

UPS does not

The UPS circuit

power essential

breaker “tripped”.

equipment

 

during an outage

 

 

The battery has

 

reached the end of its

 

life.

 

Equipment plugged

 

into a Surge Only

 

outlet.

Flashing

Internal UPS fault.

Indicators

 

Action to Take

Ensure the UPS is securely connected to an AC outlet.

Reduce the amount of equipment plugged into the “Battery Backup & Surge Protection” outlets of the UPS. Reset the circuit breaker by pushing it back in. Switch the UPS back on.

Turn off the UPS and reduce the amount of equipment connected to these outlets.

Charge the battery for 8 hours. The UPS runtime is reduced until the battery is fully charged.

Unplug non-essential equipment (printers, scanners, etc) from the Battery Backup outlets and plug into 'Surge Only' outlets

Disconnect non-essential equipment from the UPS. Reset (push in) the circuit breaker and switch the UPS on.

Plug equipment in one-at-a-time. If the circuit breaker trips again, disconnect the device that caused the breaker to trip.

Replace the battery or the battery module.

Unplug device from 'Surge Only' outlet and move to a 'Battery Backup outlet.

Contact Technical Support (see Service and Support below).

* B5: 3beeps / 30seconds :ON 0.25 seconds / OFF 0.25 seconds 3 times, 28.5seconds OFF

Recycling Information:

Your UPS contains Non-Spill Sealed Lead Batteries. On the battery you will find the battery name. Please reference the chart below for recycling