Rotel RSP-976 Controlling Zone 2 from the Remote Location, Zone 2 Audio Outputs, IR OUT Jacks

Models: RSP-976

1 24
Download 24 pages 41.21 Kb
Page 17
Image 17
To change the Zone 2 input source:

To change the Zone 2 input source:

1.Press the front panel ZONE button. The status of Zone 2 appears in the display. Make sure that Zone 2 is ON.

2.Within 10 seconds after pressing the ZONE button, press one of the INPUT SOURCE buttons to select a new source for Zone 2. The name of the selected source appears in the display.

3.Following 10 seconds with no commands, the RSP-976 reverts to normal operation.

To change the Zone 2 volume:

1.Press the front panel ZONE button. The status of Zone 2 appears in the display. Make sure that Zone 2 is ON.

2.Within 10 seconds after pressing the ZONE button, adjust the volume control to change the Zone 2 output level. The new setting appears in the display. This volume adjust- ment is only available using the VARIABLE output configuration. In FIXED output mode, the volume control for Zone 2 is disabled.

3.Following 10 seconds with no commands, the RSP-976 reverts to normal operation.

NOTE: The volume and input source controls described in this section are only available when the RSP-976 is fully activated in the main room (i.e. the display is visible). If the RSP-976 is turned off, you can only turn Zone 2 on or off from the front panel. In this case, the ZONE button is a simple toggle control – turning Zone 2 on or off with each press of the but- ton. When Zone 2 is on, the front panel STANDBY LED flashes. When Zone 2 is off, the STANDBY LED is steadily lit.

17

Controlling Zone 2 from the Remote Location

With a properly configured IR repeater sys- tem, you have full control of Zone 2 using an RR-969 remote from the Zone 2 location. You can select and operate a source, adjust the volume, and turn Zone 2 on or off. Whatever commands you send from the RR-969 will change Zone 2 and only Zone 2, just as if you were controlling a totally independent audio system in that room. These changes will have no effect on the main listening room.

To turn Zone 2 on or off, press the POWER button To change the Zone 2 volume: on the remote. To adjust the volume in Zone 2, press the VOLUME buttons Controlling Zone 2 from the Remote Location on the remote. To select a different analog input source, press one of the INPUT SOURCE but- tons Zone 2 Audio Outputs on the remote.

NOTE: The volume adjustment is only avail- able if the Zone 2 outputs are configured to use VARIABLE levels. With FIXED levels, the volume control for Zone 2 is disabled.

Zone 2 Audio Outputs ZONE REM. IN Jack

See Figure 5

These line-level RCA outputs send the Zone 2 audio signal to a stereo amplifier driving a pair of speakers in the remote zone.

Although you have the option of using an in- tegrated amplifier or a receiver to power the remote speakers, we suggest using a fixed- gain power amplifier. This simplifies system installation and operation. Your authorized Rotel dealer may make another recommendation based on specific system requirements.

To configure your system for Zone 2 opera- tion, connect the left and right Zone 2 outputs on the RSP-976 to the left and right channel inputs of the amplifier powering the remote speakers, using standard RCA audio cables.

NOTE: By default, the Zone 2 outputs provide a VARIABLE level signal, with control of the volume from the RSP-976 front panel and/or remote control from Zone 2. Alternatively, you can configure these outputs for FIXED level, which disables the volume control and sends a fixed line-level signal to an amplifier with its own volume control. See the ON-SCREEN DISPLAY/Configuration section for details.

English

ZONE REM. IN Jack IR OUT Jacks

See Figure 5

This 3.5 mm mini-jack accepts signals from a infrared repeater located in Zone 2. A third- party IR repeater system is required for op- eration of the RSP-976’s ZONE 2 functions from the remote zone.

NOTE: ZONE 2 and its IR repeater must be in a different location than RSP-976 to prevent IR commands intended to control Zone 2 from inadvertently controlling the main room op- erations.

IR OUT Jacks Manual background

See Figure 5

The IR OUT 1 & 2 jacks send IR signals re- ceived at the ZONE REM IN jack or the EX- TERNAL REM IN jack to an infrared emitter placed in front of a source component or to Rotel CD players, cassette decks, or tuners with a compatible rear panel IR connector.

This output is used to allow IR signals from Zone 2 to be sent to the source components, or to pass along IR signals from a remote in the main room when the sensors on the source compo- nents are blocked by installation in a cabinet. See your authorized Rotel dealer for information on IR repeater systems.

NOTE: The EXT REM IN jack located to the right of these jacks is for use with an external IR sensor duplicating the front panel IR sen- sor and located in the primary zone. It should not be used for ZONE 2 IR connections.

Page 17
Image 17
Rotel RSP-976 Controlling Zone 2 from the Remote Location, Zone 2 Audio Outputs, ZONE REM. IN Jack, IR OUT Jacks, English