SSA-324 Specifications

SSA-324 Specifications

Two-Wire Input

Impedance: 5,000Ω +la%, -20% single ended, 10,000Ω +100%, -20% differential

Operating Levels: -20 dBu to +0 dBu, nominal

Two-Wire Output

Impedance: 5,000Ω 20% single ended, 10.000Ω 20% differential

Operating Level: 0.1 mA to 10 mA, nominal

Four-Wire Input

Impedance: 10,000Ω minimum single ended, 20,000Ω

minimum differential operating Levels: -10 dBu to +8 dBu, nominal

Four-Wire Output

Impedance: single ended or differential

Operating Levels: -10 dBu to + 8 dBu, nominal

Transfer Functions (Duck Level set to no ducking) Voltage Gain, Four-Wire In to Two-Wire Out*

Level Pot 100% rotation: 3 dB

Level Pot 50% rotation: -15 dB 4 dB

Transfer Functions (Duck Level set to no ducking) Voltage Gain, Two-Wire In to Four-Wire Out** Level Pot 100% rotation: 22 dB 3 dB

Level Pot 50% rotation: 8 dB 4 dB

Frequency Response (Reference: 1 kHz, 0 dBu input)

Four-Wire Input to Two-Wire Output: 200 Hz to 5 kHz, +1,-4 dB, typical

Two-Wire Input to Four Wire Output: 250 Hz to 5 kHz, +1, -4 dB, typical

Signal-to-Noise Ratio (Reference: 1 kHz, 0 dBu at two- wire)

Two-Wire to Four-Wire: -60 dB

Four-Wire to Two-Wire: -60 dB

Crosstalk (Reference: 1 kHz, 0 dBu)

System A to System B,

Two-wire to Two wire 200 Hz to 5 kHz: -50 dB,

Environmental

Temperature

Operating: 0.0 to 50” Celsius

Storage: -40” to 85” Celsius

Humidity: 0 to 95%. non-condensing

Mains Voltage

Standard: 120 volts 10%, 50-60 Hz

*P Option: 230 volts 10%, 50-60 Hz

#D Option: 100 volts + 10%. -5%, 50-60 Hz

Mains Amperes

Standard: 0.20A @ 120 volts 10%, 50-60 Hz

*P Option: 0.10A @ 230 volts 10%. 50-60 Hz

#D Option: 0.22A @ 100 volts +10%,.-5%. 50-60 Hz

Dimensions

1.72” ( 44mm) high, 8.19” (208mm) wide, 8.00” (204mm) deep

Weight

SSA-324: 2.75 lbs (1.3 kg)

MCP-1: 1.0 lbs (0.45 kg)

MCP-2: 1.0 lbs (0.45 kg)

Finish

Thermoplastic front panel, aluminum case, light gray finish.

Nulling:

Manual

Contact Information

Ordering Information

Telex Communications, Inc.

 

SSA-324

 

12000 Portland Avenue South

System-to-System Interface

Burnsville, Minnesota 55337

Catalog Number: 9000697900

Telephone: 877·863·4169

SSA-324#U

Fax: 800·955·6831

System-to-System Interface

Form Number: LIT000031000

Catalog Number: 9000697921

This specifications information is preliminary and is subject to change without notification.

Date: April, 2006

 

 

Brand names mentioned are the property of their respective companies.