3 | Technical Specifications |
| |
3.1 | Operating Environment |
| |
|
|
|
|
| Parameter | Range | Comments |
Ambient Operating Temperature | Ambient Temperature as | ||
|
|
| measured from a 30cm radius |
|
|
| surrounding the center of the |
|
|
| RS900G enclosure. |
Ambient Relative Humidity | 5% to 95% | ||
Ambient Storage Temperature |
| ||
| Operating Altitude | 0 to 15240m (0 to 50000 ft) | Over temperature range of |
|
|
| to 85°C |
3.2 | Power Supply Specifications |
|
Power Supply Type
12 – 24 VDC
24VDC
48VDC
HI (125/250 VDC) 1 HI (110/230 VAC) 1
Minimum | Maximum |
Input | Input |
10 VDC | 36 VDC |
18 VDC | 36 VDC |
36 VDC | 59 VDC / |
| 72VDC |
88 VDC | 300 VDC |
85 VAC | 265 VAC |
|
|
Fuse
Rating
3.15A (T)
3.15A (T)
3.15A (T)
3.15A (T)
Isolation
1.5kV DC
1.5kV DC
1.5kV DC
4 kV AC 5.5
kV DC
Maximum Power
Consumption
10W
NOTES:
1.This is the same power supply for both AC and DC.
2.(T) denotes
3.For continued protection against risk of fire, replace only with same type and rating of fuse.
3.3Failsafe Relay Specifications
Parameter | Value |
|
|
Max Switching Voltage | 30VAC, 80VDC |
Rated Switching Current | 0.3A @ 30VAC |
| 1A @ 30VDC, 0.3A @ 80VDC |
Figure 1 - Failsafe Relay Specification
NOTES:
1.Resistive Load.
2.For
14
2008 RuggedCom Inc. All rights reserved | Rev104 |