RuggedCom RS900G Technical Specifications, Operating Environment, Power Supply Specifications

Models: RS900G

1 17
Download 17 pages 38.83 Kb
Page 14
Image 14
Technical Specifications

3

Technical Specifications

 

3.1

Operating Environment

 

 

 

 

 

 

Parameter

Range

Comments

Ambient Operating Temperature

-40 to 85°C

Ambient Temperature as

 

 

 

measured from a 30cm radius

 

 

 

surrounding the center of the

 

 

 

RS900G enclosure.

Ambient Relative Humidity

5% to 95%

Non-condensing

Ambient Storage Temperature

-40 to 85°C

 

 

Operating Altitude

0 to 15240m (0 to 50000 ft)

Over temperature range of -40

 

 

 

to 85°C

3.2

Power Supply Specifications

 

Power Supply Type

12 – 24 VDC

24VDC

48VDC

HI (125/250 VDC) 1 HI (110/230 VAC) 1

Minimum

Maximum

Input

Input

10 VDC

36 VDC

18 VDC

36 VDC

36 VDC

59 VDC /

 

72VDC

88 VDC

300 VDC

85 VAC

265 VAC

 

 

Fuse

Rating

3.15A (T)

3.15A (T)

3.15A (T)

3.15A (T)

Isolation

1.5kV DC

1.5kV DC

1.5kV DC

4 kV AC 5.5

kV DC

Maximum Power

Consumption

10W

NOTES:

1.This is the same power supply for both AC and DC.

2.(T) denotes time-delay fuse

3.For continued protection against risk of fire, replace only with same type and rating of fuse.

3.3Failsafe Relay Specifications

Parameter

Value

 

 

Max Switching Voltage

30VAC, 80VDC

Rated Switching Current

0.3A @ 30VAC

 

1A @ 30VDC, 0.3A @ 80VDC

Figure 1 - Failsafe Relay Specification

NOTES:

1.Resistive Load.

2.For Class-2 circuits only.