3.4 Twisted Pair Data Port Specifications

3.4 Twisted Pair Data Port Specifications

Data Port

Media

Distance

 

 

 

10/100 Mbps

Cat 5 UTP or STP

100m

 

 

 

Connector Type

RJ45

3.5 Fiber Optical Port Specifications

For maximum flexibility RuggedCom Inc. offers a number of different transceiver choices for Gigabit fiber optical communications. The following table details fiber optic specifications based on the order code / transceiver selected at time of ordering.

 

Order

 

 

Mode /

 

 

Tx λ

 

 

Cable

 

 

Tx Pwr

 

 

Rx

 

 

Rx

 

 

 

 

 

 

 

 

 

 

(dBm) 3

 

 

Sensitivity

 

 

Saturation

 

 

Code

 

 

Connector

 

 

(nm)

 

 

Type2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Min/Max)

 

 

(dBm) 3

 

 

(dBm) 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2LCMM

 

MM / LC

850

 

 

50/125

-9.5 / -4

 

-20

 

0

 

 

2LC10

 

SM / LC

1310

 

 

9/125

-9.5 / -3

 

-22

 

-3

 

 

2LC25

 

SM / LC

1310

 

 

9/125

-5 / 0

 

-22

 

-3

 

 

2SC10

 

SM / SC

1310

 

 

9/125

-10 / -3

 

-22

 

-3

 

 

2SC25

 

SM / SC

1310

 

 

9/125

-7

/ -3

 

-24

 

-3

 

 

SFP

 

MM / LC

850

 

 

50/125

-8.5 / -4

 

-22

 

-3

 

 

SFP

 

SM / LC

1310

 

 

9/125

-9

/ -3

 

-24

 

0

 

 

SFP

 

SM / LC

1310

 

 

9/125

-7

/ -3

 

-26

 

-3

 

 

SFP4

 

SM / LC

1550

 

 

9/125

-5 / 0

 

-26

 

0

 

 

SFP4

 

SM / LC

1550

 

 

9/125

0

/ 5

 

-26

 

0

 

 

SFP

 

SM / SC

1310

 

 

9/125

-9

/ -3

 

-22

 

-3

 

 

 

Simplex

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SFP4

 

SM / SC

1490

 

 

9/125

-9

/ -3

 

-22

 

-3

 

 

 

Simplex

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Typical

Distance1

(km)

0.5

10

25

10

25

0.5

10

25

50

80

10

10

NOTES:

1.Maximum segment length is greatly dependent on factors such as fiber quality, and number of patches and splices. Please consult RuggedCom sales associates when determining maximum segment distances.

2.All cabling is duplex type unless otherwise specified.

3.All optical power numbers are listed as dBm averages.

4.These transceivers utilize a distributed feedback (DFB) type laser and are rated for -20°C to +85°C operation only.