3. Specifications

3. Specifications

3. Specifications

3.1. Operating Environment

Parameter

Range

Comments

 

 

Ambient Temperature as measured

Ambient Operating Temperature

-40 to 85°C

from a 30cm radius surrounding the

 

 

center of the RS900GP enclosure.

 

 

 

Ambient Relative Humidity

5% to 95%

Non-condensing

 

 

 

Ambient Storage Temperature

-40 to 85°C

 

 

 

 

Operating Altitude

0 to 15240m (0 to 50000 ft)

Over temperature range of -40 to 85°C

 

 

 

Table 3.1. Operating Environment

3.2. Power Supply Specifications

3.2.1. General

 

 

 

 

 

RS900GP

Maximum

Power

Minimum Input

Maximum Input

Fuse Rating

Isolation

Maximum

Combined

Supply Type

Power

Power Output

 

 

 

 

 

 

 

 

 

Consumption

at PoE Ports

54 VDC

45 VDC

57 VDC

6.3A (T) a

1.5 kV DC

15W

273W

a(T) denotes time-delay fuse

Table 3.2. RS900GP Power Supply Specifications

3.2.2. IEEE802.3AF

Power In

Power Out

45-57 VDC, 3.5 A MAX

44-57 VDC, 15 W/PORT MAX

 

 

Table 3.3. IEEE802.3AF Power Supply Ratings

3.2.3. IEEE802.3AT

Power In

Power Out

51-57 VDC, 6 A MAX

50-57 VDC, 30 W/PORT MAX

 

 

Table 3.4. IEEE802.3AT Power Supply Ratings

3.3. Failsafe Relay Specifications

Parameter

Value

Max Switching Voltage

30VAC, 80VDC

 

 

Rated Switching Current

0.3A @ 30VAC

1A @ 30VDC, 0.3A @ 80VDC

 

 

 

Table 3.5. Failsafe Relay Specifications

• Resistive Load.

• For Class-2 circuits only.