3. Specifications
3.7. Type Test Specifications
3.7.1. IEC 61850-3 Type Tests
Test | Description |
| Test Levels | Severity | |
| Levels | ||||
|
|
|
|
| |
IEC | ESD |
| Enclosure Contact | +/- 8kV | 4 |
|
|
|
| ||
| Enclosure Air | +/- 15kV | 4 | ||
|
|
| |||
|
|
|
|
|
|
IEC | Radiated RFI |
| Enclosure ports | 20 V/m | x |
|
|
|
|
|
|
|
|
| Signal ports | +/- 2kV @ 2.5kHz | x |
|
|
|
|
|
|
IEC | Burst (Fast Transient) |
| D.C. Power ports | +/- 2kV | 4 |
|
|
|
|
|
|
|
|
| Earth ground ports | +/- 2kV | 4 |
|
|
|
|
|
|
|
|
| Signal ports | +/- 2kV | 4 |
|
|
| +/- 1.5kV | ||
IEC | Surge |
|
|
| |
|
|
|
| ||
| D.C. Power ports | +/- 1.5kV | 3 | ||
|
|
| |||
|
|
| +/- 1kV | ||
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Signal ports | 10V | 3 |
|
|
|
|
|
|
IEC | Induced (Conducted) RFI |
| D.C Power ports | 10V | 3 |
|
|
|
|
|
|
|
|
| Earth ground ports | 10V | 3 |
|
|
|
|
|
|
IEC | Magnetic Field |
| Enclosure ports | 40 A/m continuous, | N/A |
| 1000 A/m for 1 s | ||||
|
|
|
|
| |
|
|
|
|
|
|
IEC | Voltage Dips & Interrupts |
| D.C. Power ports | 30% for 0.1s, 60% for | N/A |
| 0.1s, 100% for 0.05s | ||||
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Signal ports | 2.5kV common, 1kV | 3 |
|
|
| differential mode @ 1MHz | ||
IEC | Damped Oscillatory |
|
|
| |
|
|
|
| ||
| D.C. Power ports | 2.5kV common, 1kV | 3 | ||
|
|
| |||
|
|
| differential mode @ 1MHz | ||
|
|
|
|
| |
|
|
|
|
|
|
IEC | Mains Frequency Voltage |
| Signal ports | 30V Continuous, 300V for 1s | 4 |
|
|
|
| ||
| D.C. Power ports | 30V Continuous, 300V for 1s | 4 | ||
|
|
| |||
|
|
|
|
|
|
IEC | Ripple on D.C. Power Supply |
| D.C. Power ports | 10% | 3 |
|
|
|
|
|
|
|
|
| Signal ports | 1.5kV AC (Fail- | N/A |
IEC | Dielectric Strength |
| Safe Relay output) | ||
|
|
| |||
|
|
| D.C. Power ports | 1.5kV DC | N/A |
|
|
|
|
|
|
IEC | H.V. Impulse |
| Signal ports | 5kV | N/A |
|
|
|
| ||
| D.C. Power ports | 5kV | N/A | ||
|
|
| |||
|
|
|
|
|
|
Table 3.9. RS900GP IEC 61850-3 Type Tests
RuggedCom® RuggedSwitch™ | 21 | RS900GP Installation Guide Rev 100 |