RuggedCom EMI and Environmental Type Tests, RuggedSwitchTM RS940G, IEC 61850-3 EMI TYPE TESTS

Models: RS940G

1 8
Download 8 pages 27.56 Kb
Page 5
Image 5
EMI and Environmental Type Tests

RuggedSwitchTM RS940G

8-Port Managed Gigabit Ethernet Switch

EMI and Environmental Type Tests

IEC 61850-3 EMI TYPE TESTS

TEST

Description

 

Test Levels
Severity Levels

IEC 61000-4-2

ESD

 

Enclosure Contact

+/- 8kV

4

 

 

 

 

 

Enclosure Air

+/- 15kV

4

 

 

 

 

 

 

 

 

 

IEC 61000-4-3

Radiated RFI

 

Enclosure ports

20 V/m

x

 

 

 

Signal ports

+/- 4kV @ 2.5kHz

x

 

 

 

 

 

 

 

 

 

D.C. Power ports

+/- 4kV

4

IEC 61000-4-4

Burst (Fast Transient)

 

 

 

 

 

A.C. Power ports

+/- 4kV

4

 

 

 

 

 

 

 

 

 

 

 

 

Earth ground ports 3

+/- 4kV

4

 

 

 

Signal ports

+/- 4kV line-to-earth, +/- 2kV line-to-line

4

 

 

 

 

 

 

IEC 61000-4-5

Surge

 

D.C. Power ports

+/- 2kV line-to-earth, +/- 1kV line-to-line

3

 

 

 

 

 

 

 

 

 

A.C. Power ports

+/- 4kV line-to-earth, +/- 2kV line-to-line

4

 

 

 

Signal ports

10V

3

 

 

 

 

 

 

 

 

 

D.C Power ports

10V

3

IEC 61000-4-6

Induced (Conducted) RFI

 

 

 

 

 

A.C. Power ports

10V

3

 

 

 

 

 

 

 

 

 

 

 

 

Earth ground ports 3

10V

3

IEC 61000-4-8

Magnetic Field

 

Enclosure ports

40 A/m continuous, 1000 A/m for 1 s

N/A

 

 

 

D.C. Power ports

30% for 0.1s, 60% for 0.1s, 100% for 0.05s

N/A

IEC 61000-4-29

 

 

 

 

 

Voltage Dips & Interrupts

 

 

30% for 1 period, 60% for 50 periods

N/A

 

 

 

 

 

 

A.C. Power ports

 

 

IEC 61000-4-11

 

 

100% for 5 periods, 100% for 50 periods 2

N/A

 

 

 

 

 

 

Signal ports

2.5kV common, 1kV diff. mode@1MHz

3

 

 

 

 

 

 

IEC 61000-4-12

Damped Oscillatory

 

D.C. Power ports

2.5kV common, 1kV diff. mode@1MHz

3

 

 

 

 

 

 

 

 

 

A.C. Power ports

2.5kV common, 1kV diff. mode@1MHz

3

 

 

 

 

 

 

IEC 61000-4-16

Mains Frequency Voltage

 

Signal ports

30V Continuous, 300V for 1s

4

 

D.C. Power ports

30V Continuous, 300V for 1s

4

 

 

 

 

 

 

 

 

 

IEC 61000-4-17

Ripple on D.C. Power Supply

 

D.C. Power ports

10%

3

 

 

 

 

 

 

 

 

 

Signal ports

2kVac (Fail-Safe Relay output)

N/A

 

 

 

 

 

 

IEC 60255-5

Dielectric Strength

 

D.C. Power ports

2kVac

N/A

 

 

 

 

 

 

 

 

 

A.C. Power ports

2kVac

N/A

 

 

 

Signal ports

5kV (Fail-Safe Relay output)

N/A

 

 

 

 

 

 

IEC 60255-5

H.V. Impulse

 

D.C. Power ports

5kV

N/A

 

 

 

 

 

 

 

 

 

A.C. Power ports

5kV

N/A

 

 

 

 

 

 

IEEE 1613 (C37.90.x) EMI IMMUNITY TYPE TESTS
Test

Description

 

Test Levels

Severity Levels

IEEE C37.90.3

ESD

 

Enclosure Contact

+/- 8kV

N/A

 

 

 

 

 

Enclosure Air

+/- 15kV

N/A

 

 

 

 

 

 

 

 

 

IEEE C37.90.2

Radiated RFI

 

Enclosure ports

35 V/m

N/A

 

 

 

 

 

 

 

 

 

Signal ports

+/- 4kV @ 2.5kHz

N/A

 

 

 

 

 

 

IEEE C37.90.1

Fast Transient

 

D.C. Power ports

+/- 4kV

N/A

 

A.C. Power ports

+/- 4kV

N/A

 

 

 

 

 

 

 

 

 

 

 

 

Earth ground ports3

+/- 4kV

N/A

 

 

 

 

 

 

 

 

 

Signal ports

2.5kV common mode @1MHz

N/A

 

 

 

 

 

 

IEEE C37.90.1

Oscillatory

 

D.C. Power ports

2.5kV common, 1kV diff. mode@1MHz

N/A

 

 

 

 

 

 

 

 

 

A.C. Power ports

2.5kV common, 1kV diff. mode@1MHz

N/A

 

 

 

 

 

 

 

 

 

Signal ports

5kV (Fail-Safe Relay output)

N/A

 

 

 

 

 

 

IEEE C37.90

H.V. Impulse

 

D.C. Power ports

5kV

N/A

 

 

 

 

 

 

 

 

 

A.C. Power ports

5kV

N/A

 

 

 

Signal ports

2kVac

N/A

IEEE C37.90

Dielectric Strength

 

 

 

 

 

D.C. Power ports

2kVac

N/A

 

 

 

 

 

 

 

 

 

A.C. Power ports

2kVac

N/A

 

 

 

 

 

 

Environmental Type Tests
Test
Description

 

Test Levels
Severity Levels

IEC 60068-2-1

Cold Temperature

 

Test Ad

-40°C, 16 Hours

N/A

 

 

 

 

 

 

IEC 60068-2-2

Dry Heat

 

Test Bd

+85°C, 16 Hours

N/A

 

 

 

 

 

 

IEC 60068-2-30

Humidity (Damp Heat, Cyclic)

 

Test Db

95% (non-condensing), 55°C , 6

N/A

 

cycles

 

 

 

 

 

 

 

 

 

 

 

IEC 60255-21-1

Vibration

 

Tests Fc

2g @ (10 - 150) Hz

Class 2

 

 

 

 

 

 

IEC 60255-21-2

Shock

 

Tests Ea

30g @ 11mS

Class 2

 

 

 

 

 

 

Notes: 1. Only applicable to functional earth connections separated from the safety earth connection.

2.Class 2 refers to "Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are very high, ( e.g. shipboard application and for severe transportation conditions")

www.RuggedCom.com

RuggedSwitchTM RS940G

5

 

 

 

 

 

Page 5
Image 5
RuggedCom EMI and Environmental Type Tests, RuggedSwitchTM RS940G, Port Managed Gigabit Ethernet Switch, Description