RuggedCom manual Order Codes, RuggedSwitchTM RSG2200, Port Managed Gigabit Ethernet Switch

Models: RSG2200

1 10
Download 10 pages 59.79 Kb
Page 9
Image 9
Order Codes

RuggedSwitchTM RSG2200

9-Port Managed Gigabit Ethernet Switch

Order Codes

RSG2200 -______

-______

-____

-____

-____

-____

-____

-____

-____

Main

Mount

 

PS1

PS2

S1

S2

S3

S4

S5

 

 

 

 

 

 

 

 

 

 

 

Slot 1

Slot 3

 

Slot 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Slot 2

Slot 4

 

Slot 6

 

 

 

 

 

 

 

Main: Ethernet and Power Connectors

￿.R = Ethernet on rear; LED panel on front; power connector on rear ￿.F = Ethernet on front; LED panel on front; power connector on rear ￿.B = Ethernet on rear; LED panel on top; power connector on rear ￿.T = Ethernet on front; LED panel on top; power connector on rear

Mount: Mounting Options

￿.RM = 19" Rack Mount Kit

￿.DP = DIN and Panel Mount Kit

￿.RD = 19" Rack, DIN, and Panel Mount Kit

￿.00 = No Mounting Option

PS1 and PS2: Power Supply 1 and 2

￿.24 = 24VDC (9-36VDC), screw terminal block ￿.48 = 48VDC (36-72VDC), screw terminal block ￿.HI = 88-300VDC or 85-264VAC, screw terminal block ￿.24P = 24VDC (9-36VDC), pluggable terminal block ￿.48P = 48VDC (36-72VDC), pluggable terminal block

￿.HIP = 88-300VDC or 85-264VAC, pluggable terminal block ￿.XX = No Power Supply (PS2 Only)

￿.FG71 = 2 x 1000LX GBIC - Singlemode, 1310nm, SC, 10km ￿.FG72 = 2 x 1000LX GBIC - Singlemode, 1310nm, SC, 25km ￿.FG73 = 2 x 1000LX GBIC - Singlemode, 1550nm, SC, 70km

S5: Gigabit Ethernet Modules for Slot 5

￿.XXXXX = Empty

￿.1CG01 = 1 x 10/100/1000Tx RJ45

￿.1FG01 = 1 x 1000SX - Multimode, 850nm, LC, 500m

￿.1FG02 = 1 x 1000LX - Singlemode, 1310nm, SC connectors, 10km ￿.1FG03 = 1 x 1000LX - Singlemode, 1310nm, LC connectors, 10km ￿.1FG04 = 1 x 1000LX - Singlemode, 1310nm, SC connectors, 25km ￿.1FG05 = 1 x 1000LX - Singlemode, 1310nm, LC connectors, 25km ￿.1FG50 = 1 x 1000LX SFP - Blank (no optical transceiver)

￿.1FG51 = 1 x 1000SX SFP - Multimode, 850nm, LC, 500m ￿.1FG52 = 1 x 1000LX SFP - Singlemode, 1310nm, LC,10km ￿.1FG53 = 1 x 1000LX SFP - Singlemode, 1310nm, LC, 25km ￿.1FG54 = 1 x 1000LX SFP - Singlemode, 1550nm, LC, 70km (2) ￿.1FG70 = 1 x 1000LX GBIC - Blank (no optical transceiver) ￿.1FG71 = 1 x 1000LX GBIC - Singlemode, 1310nm, SC, 10km ￿.1FG72 = 1 x 1000LX GBIC - Singlemode, 1310nm, SC, 25km ￿.1FG73 = 1 x 1000LX GBIC - Singlemode, 1550nm, SC, 70km (2)

S1, S2, S3, S4: Gigabit Ethernet Modules for Slots 1, 2, 3, and 4

￿.XXXX = Empty

￿.CG01 = 2 x 10/100/1000Tx RJ45

￿.FG01 = 2 x 1000SX - Multimode, 850nm, LC, 500m

￿.FG02 = 2 x 1000LX - Singlemode, 1310nm, SC connectors, 10km ￿.FG03 = 2 x 1000LX - Singlemode, 1310nm, LC connectors, 10km ￿.FG04 = 2 x 1000LX - Singlemode, 1310nm, SC connectors, 25km ￿.FG05 = 2 x 1000LX - Singlemode, 1310nm, LC connectors, 25km ￿.FG50 = 2 x 1000LX SFP - Blank (no optical transceiver)

￿.FG51 = 2 x 1000SX SFP - Multimode, 850nm, LC, 500m ￿.FG52 = 2 x 1000LX SFP - Singlemode, 1310nm, LC, 10km ￿.FG53 = 2 x 1000LX SFP - Singlemode, 1310nm, LC, 25km ￿.FG54 = 2 x 1000LX SFP - Singlemode, 1550nm, LC, 70km ￿.FG70 = 2 x 1000LX GBIC - Blank (no optical transceiver)

NOTES:

1 Distance ratings are typical but will depend on type of cabling, number of connectors and splices. 2 These transceivers have an operating temperature range of -20 °C to +85°C.

All other transceivers have an operating temperature range of -40°C to +85°C

Example Order Codes:

RSG2200-R-RM-HI-48-FG51-FG51-FG51-FG51-1FG51

 

19” Rack mounted, Dual power supplies (HI and 48VDC),

RSG2200-R-RM-24-XX-FG02-FG02-XXXX-XXXX-XXXXX

9 1000LX Gigabit Ethernet Ports (SFP “pluggable” optics with

19” Rack mounted, Single 24VDC power supply, 4 1000LX Gigabit

Multimode, 850nm, LC connectors), with Ethernet ports

Ethernet Ports (Singlemode 1310nm fiber, SC connectors), with

on the front.

Ethernet ports on the rear

 

RSG2200-F-RM-48-48-CG01-CG01-FG01-FG01-XXXX-XXXXX

Accessories/Options

19” Rack mounted, Dual 48VDC power supplies, 4 10/100/1000

 

RJ45 Ethernet Ports, 4 1000SX Gigabit Ethernet Ports (Multimode

82-01-0002 - Conformal Coating

1300nm fiber, LC connectors) Ethernet ports, with Ethernet ports

41-11-0011 - Cable support brackets

on the front.

43-10-0007 - Power cable (North America three

 

prong connector -> beau)

www.RuggedCom.com

RuggedSwitchTM RSG2200

9

 

 

 

 

 

Page 9
Image 9
RuggedCom manual Order Codes, RuggedSwitchTM RSG2200, Port Managed Gigabit Ethernet Switch