Technical Specifications
3 Technical Specifications 3.1 Power Supply Specifications
Input Range Power Supply
Type Min Max
Fuse
Rating
Max. Power
Consumption3
12 – 24 VDC 10 VDC 36 VDC 6.3A(F)2
48 VDC 36 VDC 59 VDC 2A(T)2
HI (125/250 VDC)1
HI (110/230 VAC)1
88 VDC
85 VAC
300 VDC
265 VAC 2A(T)1,2
25W
Notes:
1. This is the same power supply for both AC and DC.
2. (F) Denotes fast-acting fuse, (T) denotes time-delay fuse
3. Power consumption varies based on configuration. 10/100Base-TX ports
consume roughly 1W less than fiber optic ports
4. For continued protection against risk of fire, replace only with same type and
rating of fuse.
3.2 Failsafe Relay Specifications
Parameter Value (Resistive Load)
Max Switching Voltage 240VAC, 125VDC
Rated Switching Current 2A @ 240VAC
0.15A @ 125VDC, 2A @ 30VDC
Max Switching Capacity 150W, 500VA
3.3 Networking Standards Supported
Parameter 10Mbps
Ports
100Mbps
Ports
1000Mbps
Ports Notes
IEEE 802.3 9 10BaseT / 10BaseFL
IEEE 802.3u 9 100BaseTX / 100BaseFX
IEEE 802.3z 9 1000BaseSX/LX
IEEE 802.3ab 9 1000BaseTx
IEEE 802.3x 9 9 9 Full Duplex Operation
IEEE 802.1D 9 9 9 MAC Bridges
IEEE 802.1Q 9 9 9 VLAN (Virtual LAN)
IEEE 802.1p 9 9 9 Priority Levels
28
Rev100 © 2008 RuggedCom Inc. All rights reserved