Installation
Runco VX-44d/-55d Installation/Operation Manual 45
PRELIMINARY
Yaw Adjust: Loosen the Yaw/X-Adjustment Levers to allow the lens to pivot freely from
side to side. Then, angle the lens to even out any left-right pincushion distortion:
Once the proper lens angle has been set, firmly tighten the Yaw/X-Adjustment Levers to
secure the lens in place.
Geometry:
1. Input an anamorphic cross-hatch test pattern to the DHD Controller.
2. Loosen the Nylon Set Screws just enough to allow the Anamorphic Lens to rotate
freely.
3. Grasp the lens by the center ring and rotate the lens until the image is properly
anamorphic:
4. When the image geometry appears correct, tighten the set screws
to secure the lens in place. (When viewed from the front, the rear
opening on the anamorphic lens should appear as a tall, narrow
oval.)
Anamorphic Lens (Top View)
Wrong Position
Correct Position
Wrong Position Correct Position