Russound SMS3 manual Installer Options, Stream Names, Rnet Source Numbers

Models: SMS3

1 36
Download 36 pages 50.76 Kb
Page 30
Image 30

START UP

OPTIONS & STATUS CONFIGURATION

INSTALLER OPTIONS

STREAM NAMES

The SMS3’s three streams are pre-named Stream 1, Stream 2 and Stream 3. These names can be edited from this page. Select the window next to the stream name # and enter the new name using the name entry field.

Note: If used with an RNET-enabled system, changes to the SMS3 stream names appear within the graphical user interface only and DO NOT show up on the UNO keypads. UNO keypads display only source names assigned through the RNET system. To eliminate confusion, it is recommended to match the CAV/CAM source names with the media server’s stream names.

RNET SOURCE NUMBERS

When the SMS3 is used in an RNET-enabled system, the three streams are associated with source numbers within the RNET system. The SMS3’s streams are pre-configured: Stream 1=Source 3, Stream 2=Source 4, Stream 3=Source 5. These can be reassigned here, but must also be reas- signed through the RNET system. For a non-RNET system, or RNET systems that are not using all three streams, the “No RNET Source” selection is available.

30

Page 30
Image 30
Russound SMS3 manual Installer Options, Stream Names, Rnet Source Numbers