ADJUSTMENTS

WARNING:

Before performing any adjustment, make sure the bat- tery pack is removed from tool and the switch is in the OFF position. Failure to heed this warning could result in serious personal injury.

POSITIVE 0° BEVEL STOP

See Figure 23.

The saw has a positive 0° bevel stop that has been factory adjusted to assure 0° angle of the saw blade when making 90° cuts.

CHECKING POSITIVE 0° BEVEL STOP

Place the saw in an upside down position on a work- bench.

Check the squareness of the saw blade to the base of the saw using a carpenter’s square.

ADJUSTING POSITIVE 0° BEVEL STOP

Loosen bevel adjustment knob.

Turn setscrew with hex key and adjust base until it is square with the saw blade.

Tighten bevel adjustment knob securely.

ADJUSTMENT

SCREW

 

0

 

5

 

45

30

 

22

 

15

 

 

0

0

4

5

 

1

 

2

HEX NUT

POSITIVE 0°

BEVEL STOP

CARPENTER'S

SQUARE

BEVEL

ADJUSTMENT

KNOB

BLADE

WARNING:

Attempting a bevel cut without having the bevel ad- justment knob securely tightened can result in serious injury.

ADJUSTING THE LASER

See Figure 24.

NOTE:Draw a pencil line on a scrap workpiece parallel to the long edge of the base as a straight line guide to aid in the adjusting process.

Make sure the laser is turned off.

Remove the laser cover by lifting it off its base.

Turn the laser on.

Loosen the screw inside the laser.

Rest the front of the base on a scrap workpiece.

Adjust the laser beam with the mark on the scrap workpiece by loosening the screw to the laser aperture and slowly moving the laser guide left or right.

Since blade thicknesses vary, always make a trial cut in scrap workpiece to ensure an accurate cut.

Once alignment is achieved, tighten the screw.

Replace the laser cover.

Check for proper alignment.

Repeat as necessary until the laser is aligned.

LASER

COVER

SCREW

PENCIL

LINE

Fig. 23

LONG EDGE

OF BASE