14 Reference Infomation

14-3 Timing Chart

-This section of the service manual describes the timing that the computer industry recognizes as standard for computer-generated video signals.

Table 14-1 Timing Chart

Mode

IBM

 

 

 

VESA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VGA2/

VGA3/

640/75 Hz

800/60 Hz

800/75 Hz

1024/60 Hz

1024/75 Hz

1280/60 Hz

1280/75 Hz

 

70 Hz

60 Hz

 

640x480

800x600

800x600

1024x768

1024x768

1280x1024

1280x1024

Timing

720 x 400

640 x 480

 

 

 

 

 

 

 

 

 

 

fH (kHz)

31.469

31.469

37.500

37.879

46.875

48.363

60.023

63.981

79.975

A μsec

31.777

31.778

26.667

26.400

21.333

20.677

16.660

11.852

12.504

B μsec

3.813

3.813

2.032

3.200

1.616

2.092

1.219

1.037

1.067

C μsec

1.589

1.589

3.810

2.200

3.232

2.462

2.235

2.296

1.837

D μsec

26.058

26.058

20.317

20.000

16.162

15.754

13.003

9.259

9.481

E μsec

0.318

0.318

0.508

0.000

0.323

0.369

0.203

0.000

0.119

fV (Hz)

70.087

59.940

75.000

60.317

75.000

60.004

75.029

60.020

75.025

 

 

 

 

 

 

 

 

 

 

O msec

14.268

16.683

13.333

16.579

13.333

16.666

13.328

16.005

13.329

P msec

0.064

0.064

0.080

0.106

0.064

0.124

0.050

0.047

0.038

Q msec

0.858

0.794

0.427

0.607

0.448

0.600

0.466

0.594

0.475

R msec

13.155

15.761

12.800

15.840

12.800

15.880

12.795

15.630

12.804

S msec

0.191

0.064

0.027

0.0261

0.021

0.062

0.017

0.016

0.013

Clock

 

 

 

 

 

 

 

 

 

Freq.

28.322

26.175

31.500

40.000

49.500

75.000

78.750

108.000

135.000

(MHz)

 

 

 

 

 

 

 

 

 

Polarity

 

 

 

 

 

 

 

 

 

H.Sync

Negative

Negative

Negative

Positive

Positive

Negative

Positive

Positive

Positive

V.Sync

Positive

Negative

Negative

Positive

Positive

Negative

Positive

Positive

Positive

Remark

Separate

Separate

Separate

Separate

Separate

Separate

Separate

Separate

Separate

 

 

 

 

 

 

 

 

 

 

 

 

Separate Sync

 

 

Video

 

 

Video

 

 

C

D

E

Q

R

S

Sync

 

 

Sync

 

 

 

B

 

 

P

 

 

A

 

 

O

 

H/V Composite Sync

Sync-on-Green

A : Line time total

B : Horizontal sync width

O : Frame time total

P : Vertical sync width

C : Back porch

D : Active time

Q : Back porch

R : Active time

E : Front porch

 

S : Front porch

 

 

 

 

 

14-5

Page 22
Image 22
Samsung 203B service manual Timing Chart, Mode