Adjusting the Air Flow Direction Vertically
E-15
ENGLISH
Depending on the position of the indoor unit on the wall of your room,
you can adjust the position of the outer air flow blade on the bottom of
the unit, thus increasing the efficiency of the air conditioner.
1Press the SWING button one or more times as required.
Result: The outer blade is adjusted vertically.
RECOMMENDATION When... Adjust the blade to face...
Cooling Upwards.
2If you want the blade to move up and down automatically when the air
conditioner is operating, press the SWING button.
Result: The blade move up and down, around the base position set.
3
To stop the blade moving up and down, press the SWING button again.
NN
NNoo
oott
ttee
eeIf you switch the air conditioner... Then the blade is...
Off Closed completely.
On again Reset to the position that you
previously selected.
Adjusting the Air Flow Direction Horizontally
There are two sets of inner air flow blades. Just as the outer air flow
blade can be adjusted vertically, the inner blades can be adjusted
horizontally.
1Open the air flow blade along the bottom of the indoor unit, by
pressing the SWING button.
2To stop the blade moving up and down, press the SWING button
again.
3Adjust each set of inner blades to the required position, by pushing or
pulling them sideways.