Technical Specifications

 

MODEL

 

AQ09A5(6)MAF

AQ12AA(B)MCF

 

 

 

 

 

Performance

Capacity Cooling

Btu/h

9000

11500

Ratings

 

 

 

 

Capacity Heating

Btu/h

9500

12500

 

 

 

 

 

 

 

HSPF

 

7.0

6.8

 

 

 

 

 

 

SEER

 

10.0

10.0

 

 

 

 

 

 

Moisture Removal

Pts/h

3

4

 

 

 

 

 

 

Air FLOW(Cooling, HIGH)

CFM

230

261

 

 

 

 

 

 

Air FLOW(Heating, HIGH)

CFM

247

286

 

 

 

 

 

 

Sound Rating-Outdoor

dB

51

55

 

 

 

 

 

Electrical

Power source

 

115V~, 60Hz

208-230V~, 60Hz

Data

 

 

 

 

Min.Ampacity

A

8.1

5.4

 

 

 

 

 

 

 

Cooling Watts

W

950

1230

 

 

 

 

 

 

Heating Watts

W

870

1300

 

 

 

 

 

Refrigeration

Connections

 

Flare

Flare

Lines

 

 

 

 

Liquid Line O. D.

inch(mm)

41 (6.35)

41 (6.35)

 

 

 

 

 

 

Suction Line O.D.

inch(mm)

83 (9.52)

21 (12.70)

 

 

 

 

 

 

Factory Pre-charge

ft(m)

( 24 34 (7.5)

( 24 34 (7.5)

 

 

 

 

 

 

Max. Line length

ft(m)

( 49 14 (15.0)

( 49 14 (15.0)

 

 

 

 

 

 

Max. Height Difference

ft(m)

23(7.0)

23(7.0)

 

 

 

 

 

Dimensions

INDOOR UNIT

 

AQ09A5(6)MAF

AQ12AA(B)MCF

& Weight

 

 

 

 

W X H X D

inch(mm)

( 31 18 x 9 21 x 6 21 )

( 31 18 x 9 21 x 6 21 )

 

 

(790 x 245 x 165)

(790 x 245 x 165)

 

 

 

 

 

 

 

 

 

 

 

Net Weight

Ibs(kg)

21.2(9.6)

21.2(9.6)

 

 

 

 

 

 

OUTDOOR UNIT

UQ09A5(6)MAF

UQ12AA(B)MCF

 

 

 

 

 

 

W X H X D

inch(mm)

26 x 19 21 x 9 41

29 x 20 43 x 9

 

(660 x 497 x 235)

(740 x 530 x 230)

 

 

 

 

 

 

 

 

 

Net Weight

Ibs(kg)

60.7(27)

73.2(33)

 

 

 

 

 

Standard rating conditions Cooling

 

Indoor

Outdoor

 

DB

WB

DB

WB

°F

80

67

95

75

°C

26.7

19.4

35.0

23.9

Heating

Indoor

Outdoor

 

 

DB

WB

DB

WB

°F

70

60

47

43

°C

21.1

15.6

8.3

6.1