COMPLETING THE INSTALLATION

Fixing the Outdoor Unit in Position

456.5 mm

254mm

Rubber leg

The outdoor unit must be installed on a rigid and stable base to avoid any increase in the noise level and vibration, particularly if the outdoor unit is to be installed close to a neighbour.

If it is to be installed in a location exposed to strong winds or at a height, the unit must be fixed to an appropriate support (wall or ground).

1Position the outdoor unit so that the air flow is directed towards the outside, as indicated by the arrows on the top of the unit.

2Attach the outdoor unit to the appropriate support using anchor bolts.

3If the outdoor unit is exposed to strong winds, install shield plates around the outdoor unit, so that the fan can operate correctly.

Certainly fix up its rubber leg, in order to prevent its vibration and noise.

Checking and Testing Operations

To complete the installation, perform the following checks and tests to ensure that the air conditioner is operating correctly.

1

Review all the following elements in the installation:

 

Installation site strength

 

 

Piping connection tightness to detect any gas leakages

 

Connection wiring

 

 

 

Heat-resistant insulation of the piping

 

Drainage

 

 

 

Earthing wire connection

 

 

Correct operations (follow the steps below)

 

 

 

 

 

 

2

Press the

 

button.

 

 

 

 

 

 

Result:

 

The indicator lights on the indoor unit flash at half-second

 

 

 

intervals.

 

 

 

 

While the indoor unit opens, the indoor unit fan runs to start.

 

 

 

 

 

 

3

Press the

 

button.

 

 

 

Result:

The outdoor unit operates in cooling mode as following

 

 

the room temperature.

 

 

 

 

 

 

4

Air flow direction

Press the

button and check that the air flow

 

 

 

 

blades work properly.

 

 

 

 

 

 

E-14

Page 14
Image 14
Samsung AQ09NLXSER, AQ09NLNSER manual Fixing the Outdoor Unit in Position, Checking and Testing Operations