OPERATION RANGES

The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use.

MODE

OPERATIONAL TEMPERATURE

INDOOR

IF OUT OF CONDITIONS

 

INDOOR

OUTDOOR

HUMIDITY

 

 

 

 

 

 

 

 

Condensation may occur on

 

COOLING

16˚C to 32˚C

15˚C to 54˚C

80% or less

the indoor unit with risk to have

ENGLISH

either water blow off or drops on

 

 

 

 

 

 

 

 

 

 

 

 

 

the floor.

 

 

 

 

 

 

 

HEATING

27˚C or less

-5˚C to 24˚C

-

Internal protection triggers and

 

the air conditioner will stop.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Condensation may occur on

 

DRYING

18˚C to 32˚C

15˚C to 54˚C

-

the indoor unit with risk to have

 

either water blow off or drops on

 

 

 

 

 

 

 

 

 

 

the floor.

 

 

 

 

 

 

 

The standardized temperature for heating is 7˚C. If the outdoor temperature drops to 0˚C or below, the heating capacity can be reduced depending on the temperature condition.

If the cooling operation is used at over 32˚C(indoor temperature), it does not cool at its full capacity.

TECHNICAL SPECIFICATIONS

 

 

MODEL

 

 

AQ18ESAUMG

 

 

 

 

AQ24ESAUMG

 

 

STANDARD

 

ISO

 

SASO

 

ISO

SASO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAPACITY

 

 

COOL

 

18000BTU/h

 

3850kcal/h

 

24000BTU/h

5000kcal/h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEAT

 

20000BTU/h

 

5050kcal/h

 

24000BTU/h

6000kcal/h

 

 

 

 

 

 

 

 

SOURCE

 

 

 

220V~,60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CURRENT

 

 

COOL

 

 

8.8A

 

10.1A

 

12.0A

13.5A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEAT

 

 

8.2A

 

8.2A

 

12.0A

12.0A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT POWER

 

COOL

 

1900W

 

2250W

 

2600W

2900W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEAT

 

1900W

 

1900W

 

2600W

2600W

 

 

 

 

 

 

REFRIGERANT

 

KIND

 

 

 

R22

 

 

 

 

 

 

 

 

 

 

 

 

 

QUANTITY

 

 

1100g

 

 

 

 

 

1370g

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EER

 

 

COOL

 

 

9.5

 

 

6.8

 

 

9.2

6.84

 

 

HEAT

 

 

10.5

 

 

10.5

9.2

9.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR

 

DB(C/H)

27°C

 

20°C

 

29°C

 

21°C

 

27°C

 

20°C

29°C

 

21°C

TEMPERATURE

 

WB(C/H)

19°C

 

-

 

19°C

 

-

 

19°C

 

-

19°C

 

-

 

 

 

 

 

 

 

 

OUTDOOR

 

DB(C/H)

35°C

 

7°C

 

46°C

 

7°C

 

35°C

 

7°C

46°C

 

7°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WB(C/H)

24°C

 

6°C

 

24°C

 

6°C

 

24°C

 

6°C

24°C

 

6°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR

 

NET

 

 

13Kg

 

 

 

 

 

13Kg

 

WEIGHT

 

 

 

CROSS

 

 

16Kg

 

 

 

 

 

16Kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR

 

NET

 

 

40Kg

 

 

 

 

 

56Kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CROSS

 

 

44Kg

 

 

 

 

 

58Kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

appendix _35

AQ09E series_IB_E_30909A_10.12.09.indd 35

 

 

2009-10-26 10:39:06