Performing the gas leak tests

Make sure to check for gas leaks before completing the installation process (connecting the assembly pipe and hose between indoor unit and outdoor unit, insulating the cables, hose and pipe, and fixing the indoor unit to the installation plate).

A

B

Test part for outdoor unit

Tightening torque for body cap (Refer to the table)

Spindle

Charging core

R-22: Diameter of the screw - 7/16-20UNF

R-410A: Diameter of the screw - 1/2-20UNF

Tightening torque for charging port cap (Refer to the table)

C D

Test part for indoor unit

Before inspecting the leakage, use a torque wrench to close the cap for the service valve. (Comply with a tightening torque for each size of the diameter,and tighten the cap firmly to prevent any leakage.).

To check for any possible leakage, insert inert gas into the pipes connected to indoor/outdoor units and check the connection part of the indoor/outdoor units with soap lather or liquid for leakage test.

Outer Diam-

Tightening torque

 

 

eter (mm)

Body cap (N•m)

Charging port cap

(N•m)

 

 

ø 6.35

20 ~ 25

 

ø 9.52

20 ~ 25

 

ø12.70

25 ~ 30

10 ~ 12

ø15.88

30 ~ 35

 

ø19.05

35 ~ 40

 

ENGLISH

To check for gas leaks on the outdoor unit,

( 1 N•m = 10 kgf•cm )

Check the valve A and B using a leak detector.

 

To check for gas leaks on the indoor unit,

 

Check the flare nut C and D using a leak detector.

 

Leak test with nitrogen (before opening valves)

In order to detect basic refrigerant leaks, before recreating the vacuum and recirculating the R410A, it’s responsible of installer to pressurize the whole system with nitrogen (using a cylinder with pressure reducer) at a pressure above 40 bar (gauge).

Leak test (after opening valves)

Before opening valves, discharge all the nitrogen from the system and create vacuum according to page 34~36. After opening valves, check leaks using a leak detector for refrigerant.

Pump down (before disconnecting the refrigerant connections for unit repair, removal or disposal)

Pump-down is an operation intended to collect all the system refrigerant in the outdoor unit.

This operation must be carried out before disconnecting the refrigerant tubing in order to avoid refrigerant loss to the atmosphere.

Shut off the liquid valve with the Allen wrench.

Turn the system on in cooling with fan operating at high velocity.

(Compressor will immediately start, provided 3 minutes have elapsed since the last stop).

After 2 minutes of operation, shut the suction valve with the same wrench.

Turn the system off and switch mains supply off.

Disconnect tubing. After disconnection, protect valves and tubing ends from dust.

Compressor damage may occur if run at a negative suction pressure.

37

Boracay EUR_AQ09T&U@_IBIM_32447A_EN-4.indd 37

2015/7/7 14:56:40

Page 37
Image 37
Samsung AQ09TSBNCEE, AQ18TSBN Performing the gas leak tests, Tightening torque, To check for gas leaks on the outdoor unit

AQ24TSBXCEE, AQ18TSBXCEE, AQ12UGFNEUR, AQ12TSBN, AQ09UGFN specifications

The Samsung AQ09TSBN is a standout model in the realm of air conditioning units, encapsulating advanced features and technologies aimed at delivering superior indoor comfort. This compact yet powerful unit is designed for both residential and small commercial applications, ensuring an optimal climate control experience.

One of the primary characteristics of the AQ09TSBN is its energy efficiency. This air conditioner boasts an impressive Energy Efficiency Ratio (EER), helping to reduce electricity consumption while maintaining a consistent and comfortable temperature. This is particularly beneficial for users who prioritize sustainability and cost savings on their energy bills.

The unit comes equipped with Samsung's innovative Wind-Free cooling technology, which eliminates the harsh cold drafts typically associated with traditional air conditioning systems. Instead, it provides a gentle, diffused airflow that evenly distributes cool air throughout the room. This feature not only enhances comfort but also ensures that the air remains in motion without the discomfort of direct cold air, making it ideal for prolonged use.

Samsung's SmartThings integration allows users to remotely control the AQ09TSBN through a smartphone app. This smart technology enables the scheduling of cooling times, temperature adjustments, and energy monitoring, giving users the flexibility to manage their climate control needs from virtually anywhere. Additionally, voice command functionality through compatible smart devices offers an extra layer of convenience.

The AQ09TSBN is also designed with advanced filtration technology that captures dust, allergens, and other airborne particles, promoting a cleaner and healthier indoor environment. The easy-to-remove and washable filters ensure that maintenance is both simple and efficient, allowing users to keep the unit operating at peak performance.

Moreover, the air conditioner features a sleek, modern design that seamlessly fits into various interior styles. Its quiet operation allows for minimal disruption, whether in a bedroom or an office setting, further enhancing its appeal for users seeking tranquility alongside comfort.

In summary, the Samsung AQ09TSBN represents a fusion of energy efficiency, advanced technology, and user-friendly features, making it an excellent choice for individuals and businesses looking to maintain a pleasant indoor climate. With its commitment to performance and innovation, this air conditioning unit continues to lead the way in modern climate control solutions.