Optional accessories

The following connection accessories are optional. If they are not supplied, you should obtain them before installing the air conditioner.

Insulated

Insulated Assembly

Insulated Assembly Pipe,

Insulated Assembly Pipe,

PE T3 Foam Tube

Vinyl Tapes (2)

Drain Plug (1)

Assembly Pipe,

Pipe, Ø9.52mm (1)

Ø12.70mm (1)

Ø15.88mm (1)

Insulation (1)

Ø6.35mm (1)

09/10/12

18

24

 

 

 

 

 

Rubber Legs (4)

Pipe Clamps A (3)

Pipe Clamps B (3)

Cement Nails (6)

M4 x 25 Tapped

Drain Hose,

Putty 100g (1)

Screws (6)

length 2m (1)

 

 

 

 

 

ENGLISH

• If these accessories are supplied, they will be in the accessory box.

Tools required for installationGeneralTools

• Vacuum Pump(Backward flowing prevention)

• Manifold Gauge

• Stud Finder

• Torque Wrench

• Pipe Cutter

• Reamer

• Pipe Bender

• Spirit Level

• Screw Driver

• Spanner

• Drill

• L Wrench

• Measuring Tape

Tools for test operations

• Thermometer

• Resistance Meter • Electroscope

Fixing the installation plate

You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.

When facing the wall, the pipe and cable can be connected from the:

• Right (A)

• Left (B)

Direction of pipe

 

 

 

• Underside_right (C)

 

 

• Rear_right or left (D)

A

B

 

 

D

D

C

1. Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65mm so that it slants slightly downwards.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Unit : mm)

 

Pipe hole

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

A

B

C

D

 

 

 

 

 

 

 

 

 

 

 

 

 

(Ø65mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

09/10/12

27

120

68

27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

18/24

34

140

68

34

 

 

 

B

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Make sure to drill only one hole after choosing the direction of the pipe.

27

Vivaldi MAX_AQV09&12U@@ IB&IM_32450A_E.indd 27

 

 

2011-3-515:26:28