ErP Information(AC Product)

 

 

 

 

AR12HSSDAWKN / AR12HSSDAWKX

According to Commission Regulation (EU) No 206/2012

 

 

 

 

 

 

 

 

 

 

 

 

If function includes heating: Indicate the heating season the

 

Function (indicate if persent)

 

informaiont relates to. Indicated values should relate to one

 

heating season at a time. Include at least the heating season

 

 

 

 

 

 

 

 

 

 

 

 

 

'Average'

 

 

 

 

cooling

 

Y

 

Average

 

 

Y

 

 

heating

 

Y

 

Warmer

 

 

N

 

 

 

 

(if designated)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Colder

 

 

N

 

 

 

 

 

 

 

 

(if designated)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

 

symbol

value

 

unit

Item

symbol

 

value

 

unit

 

Design load

 

 

 

 

Seasonal efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

 

Pdesignc

3,5

 

kW

cooling

SEER

 

9,2

 

-

 

heating/Average

 

Pdesignh

3,0

 

kW

heating/Average

SCOP/A

 

4,8

 

-

 

heating/Warmer

 

Pdesignh

-

 

kW

heating/Warmer

SCOP/W

 

-

 

-

 

heating/Colder

 

Pdesignh

-

 

kW

heating/Colder

SCOP/C

 

-

 

-

 

Declared capacity(*) for

cooling, at indoor temperature

 

Declared energy efficiency ratio(*), at indoor temperature

 

27(19) ℃ and outdoor temperature Tj

 

 

 

27(19) ℃ and outdoor temperature Tj

 

 

 

 

Item

 

symbol

value

 

unit

Item

symbol

 

value

 

unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tj = 35 ℃

 

Pdc

3,5

 

kW

Tj = 35 ℃

EERd

 

4,1

 

-

 

Tj = 30 ℃

 

Pdc

2,5

 

kW

Tj = 30 ℃

EERd

 

6,4

 

-

 

Tj = 25 ℃

 

Pdc

1,7

 

kW

Tj = 25 ℃

EERd

 

10,8

 

-

 

Tj = 20 ℃

 

Pdc

0,8

 

kW

Tj = 20 ℃

EERd

 

19,3

 

-

 

Declared capacity(*) for

heating/Average

season, at

indoor

 

Declared coefficient of

performance(*)/Average season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

at indoor temperature 20 ℃ and outdoor temperature Tj

 

Tj = - 7 ℃

 

Pdh

2,7

 

kW

Tj = -7

COPd

 

3,1

 

-

 

Tj = 2 ℃

 

Pdh

1,7

 

kW

Tj = 2 ℃

COPd

 

4,8

 

-

 

Tj = 7 ℃

 

Pdh

1,2

 

kW

Tj = 7 ℃

COPd

 

6,1

 

-

 

Tj = 12 ℃

 

Pdh

1,1

 

kW

Tj = 12 ℃

COPd

 

7,7

 

-

 

Tj = bivalent

 

Pdh

3,0

 

kW

Tj = bivalent

COPd

 

2,8

 

-

 

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

 

Pdh

3,0

 

kW

Tj = operating limit

COPd

 

2,8

 

-

 

Declared capacity(*) for

heating/Warmer

season, at indoor

 

Declared coefficient of performance(*)/Warmer season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

at indoor temperature 20 ℃ and outdoor temperature Tj

 

Tj = 2 ℃

 

Pdh

-

 

kW

Tj = 2 ℃

COPd

 

-

 

-

 

Tj = 7 ℃

 

Pdh

-

 

kW

Tj = 7 ℃

COPd

 

-

 

-

 

Tj = 12 ℃

 

Pdh

-

 

kW

Tj = 12 ℃

COPd

 

-

 

-

 

Tj = bivalent

 

Pdh

-

 

kW

Tj = bivalent

COPd

 

-

 

-

 

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

 

Pdh

-

 

kW

Tj = operating limit

COPd

 

-

 

-

 

Declared capacity(*) for

heating/Colder

season, at indoor

 

Declared coefficient of performance(*)/Colder season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

at indoor temperature 20 ℃ and outdoor temperature Tj

 

Tj = -7

 

Pdh

-

 

kW

Tj = -7

COPd

 

-

 

-

 

Tj = 2 ℃

 

Pdh

-

 

kW

Tj = 2 ℃

COPd

 

-

 

-

 

Tj = 7 ℃

 

Pdh

-

 

kW

Tj = 7 ℃

COPd

 

-

 

-

 

Tj = 12 ℃

 

Pdh

-

 

kW

Tj = 12 ℃

COPd

 

-

 

-

 

Tj = bivalent

 

Pdh

-

 

kW

Tj = bivalent

COPd

 

-

 

-

 

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

 

Pdh

-

 

kW

Tj = operating limit

COPd

 

-

 

-

 

Tj = -15

 

Pdh

-

 

kW

Tj = -15

COPd

 

-

 

-

 

Bivalent temperature

 

 

 

 

Operating limit temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

heating/Average

 

Tbiv

-10

 

heating/Average

Tol

 

-10

 

 

heating/Warmer

 

Tbiv

-

 

heating/Warmer

Tol

 

-

 

 

heating/Colder

 

Tbiv

-

 

heating/Colder

Tol

 

-

 

 

Cycling interval capacity

 

 

 

 

Cycling interval efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for cooling

 

Pcycc

-

 

kW

for cooling

EERcyc

 

-

 

-

 

for heating

 

Pcych

-

 

kW

for heating

COPcyc

 

-

 

-

 

Degradation

 

 

 

 

 

Degradation

 

 

 

 

 

 

co-efficient

 

Cdc

0,25

 

kW

co-efficient

Cdh

 

0,25

 

-

 

cooling(**)

 

 

 

 

 

heating(**)

 

 

 

 

 

 

Electric power input in

power modes

other than

 

 

Annual electricity consumption

 

 

 

 

'active mode'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off mode

 

POFF

0,0

 

kW

cooling

QCE

 

133

 

kWh/a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

standby mode

 

PSB

0,0

 

kW

heating/Average

QHE

 

875

 

kWh/a

 

thermostat-off mode

 

PTO

0,0

 

kW

heating/Warmer

QHE

 

-

 

kWh/a

 

crankcase heater

 

PCK

0,0

 

kW

heating/Colder

QHE

 

-

 

kWh/a

 

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity control (indicate one of three options)

 

Other items

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fixed

 

N

 

 

 

Sound power level

LWA

 

58,0/62,0

 

dB(A)

 

 

 

 

 

(indoor/outdoor)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

staged

 

N

 

 

 

Global warming

GWP

 

1975

 

kgCO2 eq.

 

 

 

 

 

potential

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

variable

 

Y

 

 

 

Rated air flow

-

 

540/1920

 

m3/h

 

 

 

 

 

(indoor/outdoor)

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact details for

 

 

 

 

 

 

 

 

 

 

 

 

obtaining more

 

 

 

 

 

 

 

 

 

 

 

 

information

 

 

 

 

 

 

 

 

 

 

 

 

(*) For staged capacity

units, two values divided by a slash ('/') will be declared in each box in the section 'Declared capacity of

 

the unit' and 'declared EER/COP' of unit.

 

 

 

 

 

 

 

 

(**) If default Cd = 0,25 is chosen then (results from) cycling tests are not required. Otherwise either the heating or cooling

 

 

cycling test value is required.

 

 

 

 

 

 

 

 

 

 

Page 1
Image 1
Samsung AR12HSSDAWKNEU, AR12HSSDAWKXEU manual ErP InformationAC Product, AR12HSSDAWKN / AR12HSSDAWKX

AR12HSSDAWKNEU, AR12HSSDAWKXEU specifications

Samsung's AR series of air conditioners, including models AR24HSSDBWKNEU, AR18HSSDBWKNEU, AR09HSSDAWKNEU, and AR12HSSDAWKNEU, presents a blend of advanced technologies and thoughtfully designed characteristics to provide optimal cooling and energy efficiency for various spaces.

One of the standout features across these models is their capacity to efficiently cool different room sizes. The AR24HSSDBWKNEU, for instance, is ideal for larger spaces, while the AR09HSSDAWKNEU caters comfortably to smaller rooms. This versatility makes these units suitable for both residential and commercial applications, meeting diverse consumer needs effortlessly.

All models are equipped with Samsung's innovative Digital Inverter Technology. This technology allows the air conditioners to maintain a desired temperature consistently without frequently turning the compressor on and off, which not only ensures comfort but also leads to significant energy savings. By adjusting the compressor speed based on the cooling demand, these units operate quietly while consuming less electricity, making them an eco-friendly choice.

In addition to energy efficiency, the air purifying features are noteworthy. These air conditioners come with a multi-layered filtration system that effectively removes dust, allergens, and harmful particles from the air, enhancing indoor air quality. This is particularly beneficial for those with allergies or respiratory issues, promoting a healthier living environment.

The AR series models are also designed with user convenience in mind. They feature easy-to-navigate controls and often come with Wi-Fi connectivity for smart management. Through a dedicated app, users can operate their air conditioners remotely, allowing for pre-cooling before arriving home or adjusting settings while lounging in another room.

Another characteristic that sets these models apart is their sleek, modern design, which complements a variety of interior styles. Their compact build ensures they can fit seamlessly into any space without becoming an eyesore.

Overall, the Samsung AR24HSSDBWKNEU, AR18HSSDBWKNEU, AR09HSSDAWKNEU, and AR12HSSDAWKNEU air conditioners represent a commitment to delivering reliable performance, energy efficiency, and advanced air purification technology. For consumers looking for high-quality cooling solutions, these models are certainly a compelling choice.