Left | Right |
| Rear right or left |
Bottom right
<Possible directions of the pipe bundle>
CAUTION
•If changing the pipe direction from left to right, do not drastically bent it but slowly turn it in the opposite direction as shown. Otherwise, the pipe may be damaged in the process.
Pipe bundle hole
2Drill the hole.
CAUTION
•Be sure to drill only one hole.
•Make sure that the hole slants downwards so that the drain hose slants downwards to drain water well.
Wall
Drain hose
Indoor unit
<The hole slants downwards>
Step 1.4 Taping the pipes, cables, and drain hose
1Wrap foam insulation on parts without insulation on the ends of the refrigerant pipes, as shown in the figure. This wrapping minimises condensation problem.
Installation
<Minimum distances between the hole and the
installation plate>
|
|
|
|
| (Unit : mm) | |
|
|
|
|
|
|
|
Model | A |
| B | C |
| D |
|
|
|
|
|
|
|
AR09HSSDPWKNEE | 36 |
| 190 | 81 |
| 36 |
AR12HSSDPWKNEE |
|
| ||||
|
|
|
|
|
| |
|
|
|
|
|
| |
|
| Pipe bundle hole: Ø 65 mm |
Insulation
Refrigerant pipes
2Wind the refrigerant pipes, power cable, communication cable and drain hose with vinyl tape to make a pipe bundle.
| Refrigerant pipes |
Installation plate | (assembly pipe) |
|
Vinyl tape
Power and communication cables (assembly cable)
Drain hose
8English