• The original software version used for the product range is identified in this manual. For the software version issued at the time of manufacture, please refer to the mark plate of the indoor and outdoor units. The mark plate can be physically located on the side of both the indoor (Temperature display side) and outdoor units (Compressor side). In addition, for the current software version of the air conditioner Wi-Fi control application, please refer to the front screen of the application itself.

Outdoor unit

 

 

 

 

AR09MSPDPWKXEE

 

AR12MSPDPWKXEE

 

 

 

 

 

 

 

Dimension

Unit

Width×Height×Depth

mm

790×548×285

 

 

 

 

 

 

 

 

Weight

Unit

 

 

kg

 

37.0

 

 

 

 

 

 

 

Fan - Air flow rate

Cooling

High/Low

 

m3/min

35.0 / 10.0

Heating

High/Low

 

m3/min

35.0 / 10.0

Sound power

High

 

 

dBA

59.0

 

62.0

 

 

 

 

 

 

 

 

Sound pressure

High

 

 

dBA

44.0

 

45.0

 

 

 

 

 

 

 

Operation range

Cooling

Ambient

Min.~Max.

o C

-15 ~ 46

Heating

Ambient

Min.~Max.

o C

-30 ~ 24

 

Refrigerant

Type / Charge

 

 

kg

R-410A / 1.4

 

 

 

 

 

 

 

Add charge after 5m

 

kg/m

 

0.01

 

 

 

 

 

 

 

 

 

 

Piping

Lenght

OD - ID

Std. / Max.

m

 

5 / 15

 

 

 

 

 

 

 

connections

Level difference

ID - OD

Max.

m

 

8

 

 

 

 

 

 

Power supply

Phase / Frequency / Voltage

 

Hz / V

1~ / 50 / 220 - 240

 

 

 

 

 

 

Current - 50Hz

Maximum Fuse amps(MFA)

 

A

 

15

 

 

 

 

 

 

Compressor

Type

 

 

 

ROTARY BLDC

 

 

 

 

 

 

Expansion Device

Type / Step

 

 

 

EEV / 480

 

 

 

 

 

 

 

Motor

Type / Output

 

 

W

 

DC / 50

 

 

 

 

 

 

Base heater

Type / Output

 

 

W

SHEATH / 150

 

 

 

 

 

 

 

 