Operating Recommendations

Here are a few recommendations that you should follow when operating your air conditioner.

Topic

Recommendation

 

 

Heating

The heat pump function of the air conditioner absorbs heat from outside air and brings

performances

it indoors. As the temperature of the outside air drops, the heating performance of air

 

conditioner will decrease. If you find that the room is not warm enough, using an

 

additional heating appliance is recommended.

 

 

Frost

When outside temperature is low but humidity is high,

 

frost may form on the outdoor unit at HEAT mode.

 

If this happens:

 

The heating operation stops.

 

The defrost mode will be triggered automatically for about 10 minutes.

 

No intervention is required ; after about 10 minutes, the air conditioner operates

 

again normally.

 

 

High indoor

If both indoor and outdoor temperatures are high and the air conditioner is running

and outdoor

at HEAT mode, the outdoor unit’s fan and compressor may stop at times.

temperatures

This is normal ; simply wait until the air conditioner switches on again.

 

 

Power failure

If a power failure occurs while the air conditioner is operating, the unit will be

 

switched off. When the power returns, the air conditioner starts up again

 

automatically.

 

 

Temperature and Humidity Ranges

The following table indicates the temperature and humidity ranges, within which the air conditioner can be used.

If the air conditioner is used at...

Then...

 

 

 

High temperature

The automatic protection feature may be triggered and the air

 

 

conditioner stopped.

 

 

 

Low temperature

A water leakage or some other malfunction may happen if

 

 

the heat exchanger freezes.

 

 

 

High humidity levels

Water may condense on and drip from the surface of the

 

 

indoor unit if it is used for a long periods.

 

 

 

 

 

 

Mode

Outdoor Temperature

Indoor Temperature

Indoor Humidity

 

 

 

 

Heating

-15°C to 24°C approx.

27°C or less

-

 

 

 

 

Cooling

- 5°C to 43°C approx.

21°C to 32°C approx.

80% or less

 

 

 

 

Drying

- 5°C to 43°C approx.

21°C to 32°C approx.

-

The standardized temperature for heating is 7°C. If the outdoor temperature drops to 0°C or below, the heating capacity can be reduced depending on the temperature condition.

E-10

If the cooling operation is used at over 32°C(indoor temperature),

it does not cool at its full capacity.