4. Disassembly and Reassembly
4-1 Compressor Replacement Flow Chart
|
|
| Locate cause of defect |
|
|
|
| Release refrigerant |
|
|
| Disconnect electrical wiring |
| |
|
|
| from compressor |
|
|
|
| Cut refrigerant lines |
|
|
|
| from compressor |
|
|
|
| Plug disconnected lines |
|
|
|
| Replace compressor |
|
| Inspect electrical | Solder discharge line | Solder suction line | Use nitrogen gas |
| wiring for defects, |
|
|
|
| and terminals for |
|
|
|
| correct and secure |
|
|
|
| connections |
|
|
|
|
|
|
| Perform soldering function |
| Problem? |
|
| Fill system with nitrogen gas |
|
|
|
| |
Y | N |
|
| Check for leakage |
|
|
|
| |
|
|
|
| Y |
Corrective action |
|
| Leakage? | |
Check refrigerant oil level |
| |||
|
|
| ||
|
|
|
| N |
|
|
|
|
|
| Release nitrogen gas? | |
Y |
| Low oil level? |
| N |
|
| |
|
|
|
| ||||
|
|
|
|
| |||
Evacuate system | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Add oil as necessary |
|
|
|
|
|
| |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Recharge system | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Pinch and braze filling tube | |
|
|
|
|
|
|
|
|
Samsung Electronics |