3-2 Controls and Components
Thermostat control
Selector
LOW Fan | OFF |
| HIGH Fan |
| HIGH Cool |
| MED Cool |
| LOW Cool |
Coolest |
|
Thermostat | Selector |
3-2-1 Thermostat
•Control Operation :
By turning control knob clockwise(toward higher numbers), the temperature will be cooler.
By turning the control knob counterclockwise(toward lower numbers), the temperature will be warmer.
•Level 1 : Cool air will be supplied above 30~35°C
Cool air will be ceased below 28~32.5°C
•Level 10 : Cool air will be supplied above 11~17°C Cool air will be ceased below 7~13°C
3-2-2 Selector
•Slowly turn the Fan Selector Switch in the following order :
to LOW FAN, HIGH FAN, HIGH COOL, MED COOL, LOW COOL.
•OFF : All functions will be off.
•LOW FAN : The circulation of air is low.
•HIGH FAN : The circulation of air is maximum.
•LOW COOL : Circulation, cooling, and humidity removal are low(all simultaneousy operated).
•MED COOL : Circulation, cooling, and humidity removal are mediume(all simultaneously operated).
•HIGH COOL : Circulation, cooling, and humidity removal are maximum(all simultaneously operated).