Rinnai RHFE-431WTA Error Messages, agent and arrange for a service call, Code Displayed, Fault

Models: RHFE-431WTA

1 64
Download 64 pages 61.41 Kb
Page 42
Image 42
ERROR MESSAGES

ERROR MESSAGES

The Energysaver 431 has the ability to check its own operation continuously. If a fault occurs, an Error Message will flash on the Digital Display of the control panel. This assists with diagnosing the fault, and may enable you to overcome a problem without a service call. Please quote the code displayed when inquiring about service.

 

 

CODE DISPLAYED

FAULT

REMEDY

 

 

 

 

 

11

Ignition failure

Check gas is turned ON.

Service call if repeated.

 

 

 

 

 

 

 

 

 

12

Flame failure

Check gas is turned ON.

Service call if repeated.

 

 

 

 

 

 

 

 

 

14

Overheat

Clean filter

Service call if repeated.

 

 

 

 

 

 

 

 

 

16

Room overheat

Lower room temperature

to less than 40°C(104°F).

 

 

 

 

 

 

 

 

 

31

Room Temperature

 

 

 

 

Service call.

32

Sensor faulty

 

 

 

 

 

 

 

 

33

Overheat Temperature

 

 

 

 

Service call.

34

Sensor faulty

 

 

 

 

 

 

 

 

 

 

53

Sparker failure

Service call.

 

 

 

 

 

61

Combustion fan failure

Service call.

 

 

 

 

70

Faulty ON/OFF switch

Service call.

 

 

 

 

71

Faulty solenoids

Service call.

 

 

 

 

72

Faulty Flame Rod

Service call.

 

 

 

 

 

73

Communication Error

Turn heater OFF,

then ON again.

 

 

 

 

99

Flue block

Check around flue terminal

In all cases, you may be able to clear the Error Message simply by turning the heater OFF, then ON again.

If the Error Message still remains or returns on the next operation, contact Rinnai or your nearest service

agent and arrange for a service call.