Image 21
SLEEVE AND MANIFOLD INSTALLATION

SLEEVE AND MANIFOLD INSTALLATION

METHOD FOR STANDARD WALLS

1. Disassemble Manifold from Sleeve.

The flue consists of 3 parts, sleeve, inside connectors and tube, outside terminal; (dis-assembly by pulling hard on outside terminal and inner connections, then pull sleeve off outer terminal.)

NOTE: Clearance to combustibles for terminal assembly sleeve and flanges is 0".

2. Adjustment of Sleeve Length.

Measure wall thickness through previously drilled 3 1/8METHOD FOR STANDARD WALLS (80mm) hole.

End of sleeve should protrude 3/16"Manual background3/8" (5Manual background10mm) from outside wall. Adjust sleeve length to wall thickness plus 3/16"Manual background3/8" (5Manual background10mm). (Sleeve is threaded for adjustment.) Do not extend beyond red line.

3. For S and A flue only.

Depending on flue set and wall thickness extension piece “C” may need to be removed.

Cut plastic, remove extension, then follow instruction 2. This applies to “S” and “A” flues only.

There is no extension on other flues, they can be fully adjusted by turning the threaded section.

4. Fixing Sleeve.

Fix to the wall, using the 3 screws provided.

NOTE: The flange is marked “TOP”, sleeve must be fitted with this mark Up. Check sleeve protrudes 3/16" Manual background3/8" (5Manual background10mm) on the outside.

Flanges

Connection Sleeve Terminal

Do not extend beyond red line

Extension joint

Extension

under plastic

("S" and "A" flues only)

Adjust length by turning sleeve.

A BC

 

Remove extension at this

"A" Flue only

point it necessary.

5-10mm

"TOP"

° 2

Fixing Screw

Don't remove green plastic covering from sleeve.

– 19 –