■TYPES COMPATIBLE WITH EXTENSION SET

TYPES COMPATIBLE WITH EXTENSION SET

INSTALLING AN EXTENSION KIT

Installing an extension kit requires construction of an air line and the exhaust line. The air line is connected between the Air Supply Elbow at the rear of the heater and the air inlet port on the Flue pipe.

Similarly, the exhaust line is connected between the joint pipe at the rear of the heater, and the exhaust port on the Flue pipe.

Caution: Check to see there is no debris in pipe or hose.

HOW TO INSTALL

Example:Using 2 sets of extension set and 1 bent set.

Pipe stopper A

Pipe stopper B

 

Pipe stopper A

 

Bent elbow

 

Pipe stopper A

Hose joint

 

Air intake elbow

Pipe stopper B

(comes with main unit)

 

Vent manifold

 

(comes with main unit)

Exhaust pipe

 

Hose joint

 

Air intake hose

Pipe stopper A

 

 

Pipe stopper B

Example:Using 80 inches slide pipe set.

Vent manifold

 

(comes with main unit)

 

Air intake elbow

Pipe stopper A

(comes with main unit)

Pipe clamp

 

 

Pipe stopper B

Pipe clamp

Exhaust pipe

 

 

Pipe stopper A

Pipe clamp

 

 

40 inch straight pipe

Pipe clamp

 

Hose joint

Pipe stopper A

Air intake hose

Pipe stopper B

 

1. How to connect exhaust pipes

 

Exhaust pipe

 

Exhaust pipe

 

Fit inside

 

Female end

Male end

Female end

Male end

 

 

 

Pipe stopper B

Pipe stopper B

Pipe stopper A

To connect the exhaust pipes, fit the male end into the female end and clamp with pipe stopper A to prevent slipping. The exhaust pipe can be telescoped to the required length; do not cut it.

Female end

 

Male end

Connect bent pipe

 

 

 

 

 

 

Fit inside

Pipe stopper A