Specifications
NOTE: Specifications are subject to change without prior notice.
Electrical Specifications
Nominal input network voltage | 12 Vdc |
|
|
Maximum operating current | 200 mA @ nominal input network voltage |
|
|
Relay contact voltage rating | 12 Vdc, 30 Vdc max.* |
|
|
Maximum relay contact current | 5 A DC* |
|
|
Nominal 12/24 V thermostat | 12 Vdc/24 Vdc* = On |
input voltage |
|
|
|
Minimum 12/24 V thermostat | 9.5 Vdc* |
input voltage |
|
|
|
Maximum 12/24 V thermostat | 30 Vdc* |
input voltage |
|
|
|
Typical 12/24 V thermostat | 14.6 mA @ 12 V |
input current |
|
|
|
Nominal 12/24 V generator running | 12 Vdc/24 Vdc*= On |
B+ voltage |
|
|
|
Minimum 12/24 V generator running | 9.5 Vdc* |
B+ voltage |
|
|
|
Maximum 12/24 V generator running | 30 Vdc* |
B+ voltage |
|
|
|
Typical 12/24 V generator running | 14.6 mA @ 12 V |
B+ current |
|
|
|
Communication physical layer | 2, CAN |
|
|
Electrical Specifications
Communication protocol | Xanbus |
|
|
Maximum cable length | 130 ft. (40 m) |
|
|
Environmental Specifications
Operating temperature | |
|
|
Storage temperature | |
|
|
Maximum case temperature | 140 °F (60 °C) |
|
|
Operating humidity | 5 to 95% |
|
|
Storage humidity | 5 to 95% |
|
|
Ignition protection | None |
|
|
Regulatory Approvals
Safety | CSA certified to CSA |
| Ed. including the marine supplement |
|
|
EMC | FCC Part 15, Class B |
| Industry Canada |
|
|
73 |