Xantrex Technology 809-0915 manual Troubleshooting

Models: 809-0915

1 100
Download 100 pages 27.4 Kb
Page 80
Image 80

Troubleshooting

Warning Reference Table

Table 6

AGS Warning Messages

 

 

 

 

 

 

 

Warning

Message

Self-clearing?

Cause

Action

Number

 

 

 

 

 

 

 

 

 

W200

Generator

No

Generator was stopped

Acknowledge the

 

was stopped

 

by an external Manual

warning. To resume

 

manually.

 

Off switch.

automatic starts and

 

 

 

 

stops, change the AGS

 

 

 

 

mode to [Automatic].

 

 

 

 

 

W201

Generator

No

Generator was started

Acknowledge the

 

was started

 

by an external Manual

warning. To resume

 

manually.

 

On switch

automatic starts and

 

 

 

 

stops, change the AGS

 

 

 

 

mode to [Automatic].

 

 

 

 

 

W202

Unable to

Yes

The AGS tried, but

No action required. The

 

start

 

could not start the

AGS will try to start the

 

generator.

 

generator.

generator again until it

 

AGS will try

 

 

reaches the maximum

 

again.

 

 

number of start tries.

 

 

 

 

 

W203

Manual Off:

No

The generator has run

Acknowledge the

 

Max

 

for its maximum

warning. Return the

 

generator run

 

allowable time. The

AGS to the desired

 

time reached.

 

AGS has stopped the

GenMode [Automatic

 

Reset

 

generator and changed

or ManualOn]. Ensure

 

GenMode.

 

the GenMode to

generator has fuel and

 

 

 

[ManualOff].

is supplying the

 

 

 

 

required power for

 

 

 

 

battery charging and

 

 

 

 

loads.

 

 

 

 

 

Table 6

AGS Warning Messages (Continued)

 

 

 

 

 

 

Warning

Message

Self-clearing?

Cause

Action

Number

 

 

 

 

 

 

 

 

 

W205

Generator

Yes

The generator was

Check your generator.

 

started by its

 

started, but not by the

Stop it using the switch

 

switch. Use

 

AGS.

or control panel on the

 

its switch to

 

 

generator.

 

stop.

 

 

 

 

 

 

 

 

W206

Mismatched

No

You have set a start

Acknowledge warning

 

triggers.

 

trigger, but not a

and set a stop trigger.

 

Enable stop

 

corresponding stop

 

 

trigger or

 

trigger.

 

 

disable start

 

 

 

 

trigger.

 

 

 

 

 

 

 

 

W207

Mismatched

No

You have set a stop

Acknowledge warning

 

triggers.

 

trigger, but not a

and set a start trigger.

 

Enable start

 

corresponding start

 

 

trigger or

 

trigger.

 

 

disable stop

 

 

 

 

trigger.

 

 

 

 

 

 

 

 

W208

Automatic

No

You are attempting to

Acknowledge warning

 

start and stop

 

enter Automatic Mode

and set start and stop

 

triggers not

 

without setting triggers.

triggers.

 

enabled.

 

 

 

 

Configure

 

 

 

 

triggers.

 

 

 

 

 

 

 

 

70

Xanbus Automatic Generator Start (AGS) Owner’s Guide

Page 80