Xanbus Automatic Generator Start Installation

Type 3

Type 3 is a three-wire GlowStop with shutdown bypass configuration. The configuration shown in Figure 9 uses a shutdown bypass output to temporarily disable the generator’s low oil pressure shutdown functionality during cranking. Generators with this functionality often have a manual means of disabling it during cranking.

AGS Harness W ires

Generator W ires

Relay Function

Preset Configuration Setting

 

 

Preheat to crank delay

0 s

 

 

Crank time

15 s

 

 

Crank retry time

30 s

 

 

Gen Cool Down

30 s

 

 

Gen Spin Down

3 s

 

 

Shutdown bypass time

10 s

12

13

14

Relay 1

16

17

Relay 2

18

5A fuse

5A fuse

GENERATOR RUN SIGNAL GENERATOR RUN SIGNAL RETURN

PREHEAT

STOP

BYPASS SHUTDOWN START

Start tries

3

For additional information, see “Circuit Limitations” on page 11.

Figure 9 Type 3 Connection Diagram

Relay Function

Preset Configuration Setting

 

 

Relay 1 mode

GlowStop/Shutdown bypass

Relay 3 mode

Preheat/Shutdown bypass

 

 

Gen Run signal hold time

0.5 s

 

 

Preheat time

20 s

 

 