Xanbus Automatic Generator Start Installation

Routing Connections

EXPLOSION HAZARD

This equipment is not ignition protected. To prevent fire or explosion, do not install the AGS in locations that require ignition-protected equipment. This includes any space containing gasoline-powered machinery, fuel tanks, as well as joints, fittings, or other connections between components of a fuel system.

Follow all relevant instructions exactly before installing or using your AGS.

SHOCK AND ENERGY HAZARDS

Before making any connections to the generator, ensure that the generator’s starter is disabled and the generator’s start battery is disconnected.

Failure to follow these instructions will result in death or serious injury.

Connection Types Because the AGS will be part of a Xanbus system, it is necessary to consider how to route two types of connections:

connections to the generator, thermostats, and other external devices and switches, using the included 20-contact connector and wiring harness.

connections to other Xanbus-enabled devices, using network cables.

Network ports

Network cables to other Xanbus- enabled devices

Figure 5 AGS External Connections

20-contact connector

Wiring harness (connection to generator, thermostats, and external switches)

975-0082-01-01

9

Page 19
Image 19
Xantrex Technology 809-0915 manual Routing Connections, Shock and Energy Hazards