Xantrex Technology 809-0915 manual Using Quiet Time, To enable Quiet Time

Models: 809-0915

1 100
Download 100 pages 27.4 Kb
Page 76
Image 76

Operation of the Xanbus AGS

Using Quiet Time

Use the Quiet Time feature to ensure that the AGS will not start the generator during the night or during times that conflict with local noise restrictions.

Using Quiet Time involves three steps.

1."QT En" must be set to [Enabled]. The default setting is [Enabled].

2."QT Begin" must have an appropriate time set for Quiet Time to start on schedule. The default setting for "QT Begin" is [9:00 PM] or 21:00 if using a 24-hour clock.

3."QT End" must have an appropriate time set for Quiet Time to stop on schedule. The default setting for "QT End" is [8:00 AM] or 8:00 on the 24-hour clock.

For more information about Quiet Time settings, see “QT En” on page 40, “QT Begin” on page 41, and “QT End” on page 42.

To enable Quiet Time:

1.On the Auto Gen Start menu, use the arrow buttons to highlight "QT En".

2.Press Enter.

3.Use the arrow buttons to select [Enabled].

4.Press Enter.

To set the beginning of Quiet Time:

1.On the Auto Gen Start menu, use the arrow buttons to highlight "QT Begin", then press Enter.

2.Use the arrow buttons to select the hour, then press Enter.

3.Use the arrow buttons to select the minutes, then press Enter. If the 24-hour clock is being used, go to step 5.

4.Use the arrow buttons to select AM or PM, then press Enter.

5.Press Exit twice to return to the System Home screen.

To set the end of Quiet Time:

FSW System Home Screen

System Status

Battery

20.4A

53.9V

BatLev

 

 

E--F

Load

 

 

1235W

AC1

1150W

3202V

Menu

Select Device Menu

 

AGS Menu

Set Quiet Time settings

 

 

 

 

 

 

 

 

 

Select Device

 

 

XAGS 00: Setup

 

 

XAGS 00: Adv

 

System Settings

 

 

Advanced Settings

 

 

QT En

[Enabled]

FSW3012

 

 

GenMode

[ManualOff]

 

 

QT Begin

[10:00AM]

EMS

 

 

Clear Faults Warnings

 

 

QT End

[7:00AM]

XAGS

 

 

 

View Device Info

 

 

Gen Type

[2]

 

 

 

 

 

 

 

 

 

 

1.

On the Auto Gen Start menu, use the arrow buttons to highlight "QT

 

End", then press Enter.

2.

Use the arrow buttons to select the hour, then press Enter.

3.

Use the arrow buttons to select the minute, then press Enter.

 

If the 24-hour clock is being used, go to step 5.

4.

Use the arrow buttons to select AM or PM, then press Enter.

Figure 35 Using the Quiet Time Feature

5. Press Exit twice to return to the System screen.

66

Xanbus Automatic Generator Start (AGS) Owner’s Guide

Page 76
Image 76
Xantrex Technology 809-0915 manual Using Quiet Time, To enable Quiet Time