Xanbus Automatic Generator Start Installation
Connecting the AGS to the Xanbus Network
EQUIPMENT DAMAGE
Connect only to other
Although the cabling and connectors used in this network system are the same as those used for Ethernet, this network is not an Ethernet system. Equipment damage may result from attempting to connect a Xanbus- enabled device to an Ethernet system.
Failure to follow these instructions can damage the unit and/or damage other equipment.
To connect the AGS to the Xanbus network, plug a Xanbus network cable (standard
.
Shore
Power
System Control Panel | Automatic Generator Start | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
network terminator
Generator
Freedom Sequence
AC Loads
AC Panel
BATTERY
Freedom SW Inverter/Charger
Inverter
Load Panel
network terminator
cable to the next
Figure 25 Xanbus Network Example
If the AGS is being installed on an existing Xanbus system, the system must first be put into Standby. See “Putting the AGS in Standby Mode” on page 67.
Depending on the layout of the Xanbus system, the following options are available for the other network connector on the AGS:
•A second network cable
•A network terminator (when the AGS is the last device at one end of the network)
34 | Xanbus Automatic Generator Start (AGS) Owner’s Guide |