4. Disassembly and Reassembly
4-1 Replacement of Magnetron, Motor Assembly and Lamp
Remove the magnetron including the shield case, permanent magnet, choke coils and 500pF
Cover Air
capacitors (all of which are contained in one assembly).
1. Disconnect all lead wires from the magnetron |
and lamp. |
Lamp
Thermo S/W
Fan Motor
2. Remove the bracket mounting. |
3. Remove the air cover. |
4. Remove screws securing the magnetron to the |
wave guide. |
5. Take out the magnetron very carefully. |
6. Remove screws from the back panel. |
7.Remove the assy noise filter. |
8. Take out the fan motor. |
9. Remove the oven lamp by pulling out from hole |
of air cover carefully. |
10. NOTE1: When removing the magnetron, make |
sure that its antenna does not hit any |
adjacent parts, or it may be damaged. |
11. NOTE2: When replacing the magnetron, be |
sure to remount the magnetron gasket |
in the correct position and make sure |
the gasket is in good condition. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Screw |
Magnetron | H. V. Trans |
|
| ||
|
|
| |||
|
| V. Capacitor | |||
|
| H. |
4-2 Replacement of High Voltage Transformer
1.Discharge the high voltage capacitor.
2.Disconnect all the leads.
3.Remove the mounting bolts.
4.Reconnect the leads correctly and firmly.
PRECAUTION
Servicemen should remov their watches whenever working close to or replacing the magnetron.
PRECAUTION |
|
|
| |
There exists HIGH VOLTAGE ELECTRICITY with high |
|
|
| |
current capabilities in the circuits of the HIGH |
|
|
| |
VOLTAGE TRANSFORMER secondary and filament |
|
|
| |
terminals. It is extremely dangerous to work on or |
|
|
| |
near these circuits with the oven energized. |
|
|
| |
Bolts |
| |||
H. V. Trans | ||||
DO NOT measure the voltage in the high voltage |
|
| ||
|
|
| ||
|
|
|
circuit including filament voltage of magnetron.
Samsung Electronics |